Dugan Model E User Guide
Web Control Panel
26
The Model E’s factory default IP address is 192.168.0.1. Note that the subnet is 0,
which keeps the Model E from interfering with other network devices, but also prevents
it from being recognized by most networks. The method to change the IP address depends
on whether the Model E is connected directly to a computer or to a network router/switch.
In either case, drag
Index.htm
to a web browser. If the message in Figure 5-2 is dis-
played, click
OK
to close the error message (if not, the IP address does not need to be
changed and proceed to
Operation
on page 28).
Figure 5-2
Error message
The Network Info dialog (Figure 5-3) appears, showing the computer’s
Local IP Address
at the top.
Figure 5-3
Network Information dialog
The subnet is the third group of digits in the
Local IP Address
(1 in Figure 5-3). Now
follow the appropriate instructions for your connection to modify the unit’s IP address.
Summary of Contents for E
Page 4: ......
Page 20: ...Dugan Model E User Guide Installation 20 ...
Page 46: ...Dugan Model E User Guide Specifications 46 ...
Page 48: ......