Dugan Model E User Guide
Installation
17
3.3.2
Digital
Adjust the console input gain trimmers so that talking signal levels at the sends are
between -20 and 0 dBFS, and room noise at the sends is higher than -75 dBFS. Console
input gains should be high enough so the
level
lights stay green all the time, but do not
turn red on peaks.
3.4
Power-up Commands
The Model E can execute one of six commands during each power-up. Select the com-
mand by holding down a specific button during the entire power-up process. Power-up
is complete after the
bypass
LEDs light sequentially and extinguish.
System Reset
Hold the channel 1
bypass
button down to set all parameters to factory default settings,
clear label text, and set the I/O to analog. We recommend starting an installation in this
mode.
Network Reset
Hold the channel 1
mute
button down to set these parameters to their default values:
IP
:
192.168.0.1
Netmask
:
255.255.255.0
DNS
:
192.168.0.254
Gateway
:
192.168.0.254
DHCP
:
off
DHCP On
Turning DHCP on requests that the network assign an IP number to the Model E, if the
network has that capability. To turn DHCP on, hold the channel 2
bypass
button down.
Display IP Address
Hold the channel 2
mute
button down to display the address for 30 seconds. The bottom
four LEDs of each bargraph represent one digit in hexadecimal format.