4M Stop Action Camera Manual
PRELIMINARY
DALSA 03-32-10121-09
19
-0:0-511
9200/57600/115200/
2/3/4/7/
89 [us]
1-2352:1-1728:0-1023
60/320/
1728:0-12287
f 1.0-62.1 [Hz]
ti 0-2:0-65535
5/6/7/8/9/10/
iixyxy 0-0:1-1:1-1:1-1725:2352-
2352:4-1728
i 0-1
wts window trigger source m 1/2/
s write
r settings
s
Syntax:
gcp
3.1 First
a is powered up for the first time, it operates using the following factory
•
Flat field coefficients enabled (calibrated in exposure mode 2, 55 fps, and
exposure time of 2 ms)
•
Exposure mode 2
•
60 fps
•
14992.6 µs exposure time
•
Camera Link mode 16 (Medium configuration, 4 taps. 10 bits)
h help
lpc load pixel coefficient
rc reset camera
rfs restore factory settings
rpc reset pixel coefficients
rus restore user settings
sao set analog offset ti 0
sbr set baud rate m 9600/1
sem set exposure mode m
set set exposure time f 10-9999
sfc set fpn coefficient xyi
sot set output throughput m 2
spc set prnu coefficient xyi 1-2352:1-
ssb set subtract background ti 0-2:0-511
ssf set sync frequency
ssg set system gain
svm set video mode m 0/1/2/3/4/
vt verify temperature
vv verify voltages
wfc write fpn coefficients
wpc write prnu coefficients
wse window start end
Retrieving Camera Setting
To retrieve current camera settings, use the command:
Power Up Camera Settings
When the camer
settings:
PT-41-04M60
wss window set sequence
wu
use