Spyder3 GigE Vision User Manual
03-032-20027-02
DALSA
80
Mnemonic
Syntax Parameters Description
set exposure time
set
f
Sets the exposure time. Refer to the
camera help screen (
h
command) for
allowable range.
set fpn coeff
sfc
x i
Set the FPN coefficient.
x
=pixel number within the range
1
to
sensor pixel count
.
i
= FPN value within the range
0
to
2047
(12-bit LSB).
set GPIO input
sgi
i1 i2
Sets the GPIO input signal.
i1
= input number in a range from
0
to
3
i2
= signal to use where:
0
= disabled
1
= TTL
2
= LVDS
Note:
sgi 3 2
is not available.
set GPIO output
sgo
i1 i2
Sets the GPIO output signal.
i1
= output number in a range from
0
to
3
i2
= output signal to use where:
0
= disabled
1
= TTL
2
= LVDS
PUT NOTE here that sgi 3 2 is not
available
set lower threshold
slt
i
The pixels below the lower threshold
are checked for and reported in the
end-of-line sequence in a range from
0
-
4095
.
set prnu coeff
spc
x i
Set the PRNU coefficient.
x
=pixel number within the range
1
to
sensor pixel count
.
i
= PRNU value within the range
0
to
28671
.
set readout mode
srm
i
Set the readout mode in order to clear
out dark current charge in the vertical
transfer gates before the sensor is read
out.
0
= Auto.
1
= Dark current clear.
2
= Immediate readout. Does not clear
dark current.
set subtract background
ssb
t i
Subtract the input value from the
output signal.
t
= Tap value.
0
for all taps or
1
to
number of camera taps
for individual tap
selection.
i
= Subtracted value in a range from
0
to
4095
.
Summary of Contents for Spyder3 SG-11-01k80-00-R
Page 14: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 14...
Page 30: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 30...
Page 82: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 82...
Page 88: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 88...
Page 90: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 90...