Spyder3 GigE Vision User Manual
03-032-20027-02
DALSA
78
Mnemonic
Syntax Parameters Description
get signal frequency
gsf
i
Reads the requested Camera Link
control frequency.
1
= EXSYNC frequency
2
= Spare
3
= Direction
4
= Spare
get status led
gsl
Returns the current state of the
camera’s LED where:
1
= Red
2
= Green
5
= Blinking green
6
= Blinking red
help
h
Display the online help.
load pixel coefficients
lpc
Loads the previously saved pixel
coefficients from non-volatile memory
where
i
is:
0
= Factory calibrated coefficients
1
= Coefficient set one
2
= Coefficient set two
3
= Coefficient set three
4
= Coefficient set four
reset camera
rc
Resets the entire camera (reboot). Baud
rate is not reset and reboots with the
value last used.
restore factory settings
rfs
Restores the camera’s factory settings.
FPN and PRNU coefficients reset to 0.
region of interest
roi
x y x y
Sets the pixel range affected by the
cag
,
cao
,
gl
,
gla
,
ccf
, and
ccp
commands.
The parameters are the pixel start and
end values (
x
) and the column start and
end values (
y
) in a range from
1
to
sensor pixel count
.
reset pixel coeffs
rpc
Resets the pixel coefficients to 0.
restore user settings
rus
Restores the camera's last saved user
settings and FPN and PRNU
coefficients.
set analog gain
sag
t f
Sets the analog gain in dB.
t
= tap selection, either
1
or
2
depending on camera model, or
0
for
all taps.
f
= gain value specified from
–10
to
+10
(1k and 2k models only.)
Summary of Contents for Spyder3 SG-11-01k80-00-R
Page 14: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 14...
Page 30: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 30...
Page 82: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 82...
Page 88: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 88...
Page 90: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 90...