Spyder 3 GigE User’s Manual
DALSA 03-032-10158-06
97
Mnemonic
Syntax Parameters Description
calculate PRNU
algorithm
cpa
i i
Performs PRNU calibration according
to the selected algorithm.
The first parameter is the algorithm
where
i
is:
1
= This algorithm first adjusts each
tap’s analog gain so that 8-13% of pixels
within a tap are above the value
specified in the target value parameter.
PRNU calibration then occurs using the
peak pixel in the region of interest.
(Identical to
ccp
)
2
= Calculates the PRNU coefficients
using the entered target value as shown
below:
PRNU Coefficient =
Target
(AVG Pixel Value) - (FPN+
value)
sdo
The
calculation is performed for all sensor
pixels but warnings are only applied to
pixels in the region of interest. This
algorithm is useful for achieving
uniform output across multiple
cameras.
3
= This algorithm includes an analog
gain adjustment prior to PRNU
calibration. Analog gain is first adjusted
so that the peak pixel value in tap’s ROI
is within 97 to 99% of the specified
target value. It then calculates the
PRNU coefficients using the target
value as shown below:
PRNU
Coefficient
=
Target
(AVG
Pixel
Value
)
‐
(FPN
+
value)
sdo
i
i
i
The calculation is performed for all
sensor pixels but warnings are only
applied to pixels in the region of
interest. This algorithm is useful for
achieving uniform output across
multiple cameras.
The second parameter is the target
value to use in a range from
1024
to
4055
DN.
correction set sample
css
m
Sets the number of lines to sample
when using the gla command or when
performing FPN and PRNU calibration
where m is
256
,
512
, or
1024
display gpio
configuration
dgc
Displays the current configuration of
the GPIO connector.
display pixel coeffs
dpc
x1 x2
Displays the pixel coefficients in the
order FPN, PRNU, FPN, PRNU, …
x1
= Pixel start number
x2
= Pixel end number
in a range from
1
to
1024
or
2048
Summary of Contents for spyder SG-10-01k40
Page 16: ...Spyder 3 GigE User Manual 03 032 10158 06 DALSA 16 ...
Page 30: ...Spyder 3 GigE User Manual 03 032 10158 06 DALSA 30 ...
Page 36: ...Spyder 3 GigE User Manual 03 032 10158 06 DALSA 36 ...
Page 42: ...Spyder 3 GigE User Manual 03 032 10158 06 DALSA 42 ...
Page 46: ...Spyder 3 GigE User Manual 03 032 10158 06 DALSA 46 ...
Page 114: ...Spyder 3 GigE User Manual 03 032 10158 06 DALSA 114 ...