Spyder 3 GigE User Manual
03-032-10158-06
DALSA
102
Mnemonic
Syntax Parameters Description
set video mode
svm
i
Switch between normal video mode
and camera test patterns:
0
: Normal video mode
1
: Camera test pattern
2
: Camera test pattern
update gain reference
ugr
Changes 0dB gain to equal the current
analog gain value set with the
sag
command.
verify temperature
vt
Check the internal temperature of the
camera
verify voltage
vv
Check the camera’s input voltages and
return OK or fail
write FPN coefficients
wfc
i
Write all current FPN coefficients to
EEROM where
i
is:
1
= FPN coefficient set one
2
= FPN coefficient set two
3
= FPN coefficient set one
4
= FPN coefficient set two
write PRNU coeffs
wpc
i
Write all current PRNU coefficients to
EEROM where
i
is:
1
= PRNU coefficient set one
2
= PRNU coefficient set two
3
= PRNU coefficient set one
4
= PRNU coefficient set two
write user settings
wus
Write all of the user settings to EEROM.