Camera Output Format
How to Configure Camera Output
The Piranha HN cameras offer great flexibility when configuring your camera output. Using the
clm
command, you determine the camera’s Camera Link configuration, number of output taps, and bit depth.
Using the
sot
command, you determine the camera’s output rate. These two commands work together to
determine your final camera output configuration.
You can further configure your readout using the
smm
command to select the camera’s pixel readout
direction.
The following tables summarize the possible camera configurations. Refer to the figure below for a
description on how to select your camera output.
Figure 14: How to Read the Camera Link Tables
Note:
In the following tables the Camera Link taps refer to the way the data is configured for output over
Camera Link.1.3 Image Sensor