Linea ML Multiline Monochrome / HDR CMOS Cameras
•
23
•
When using a 12 V supply, voltage loss in the power cables will be greater due to the higher
current. Use the Camera Information category to refresh and read the camera’s input
voltage measurement. Adjust the supply to ensure that it reads above or equal to 12 V.
Note: If your power supply does not meet these requirements, then the camera performance
specifications are not guaranteed.
Power and GPIO Connections
The camera uses a single 12-pin Hirose male connector for power, trigger and strobe signals. The
suggested female cable mating connector is the Hirose model HR10A-10P-12S.
12-Pin Hirose Connector Signal Details
The following figure shows the pinout identification when looking at the camera’s 12-pin male
Hirose connector. The table below lists the I/O signal connections.
1
4
6
7
12
11
3
2
10
8
9
5
Pin Number
Input / Output
Signal Details
Notes
1
Power Ground*
2
+12 V to +24 V power*
3
Output
Line 3 Out
0 to 3.3V TTL
4
Output
Line 4 Out
0 to 3.3V TTL
5
Input
Line 1 / Trigger / Phase A
0 to 3.3V TTL
6
Input
Line 2 / Scan Direction / Phase B
0 to 3.3V TTL
7
Output
Line 5 Out
0 to 3.3V TTL
8
Output
Line 6 Out
0 to 3.3V TTL
9
Power Ground*
10
+12 V to +24 V power*
11
Signal Ground
Note: intended as a return path for
GPIO signal and not intended as a
power ground
12
Signal Ground
Note: intended as a return path for
GPIO signal and not intended as a
power ground
*Connect all power pins. Each pin is rated 2A.
The wire gauge of the power cable should be sufficient to accommodate a surge during power-up of