Camera Performance and Features
25
Measuring Line (Trigger) Rate
See Camera Control Category in Appendix A for GenICam features associated with this section and
how to use them.
Related Feature: Measured Line Rate
The Measured Line Rate command is used to read the line (trigger) rate being applied, externally
or internally, to the camera.
Maximum Line Rate
The maximum line rate that the camera can achieve is determined by the number of CLHS lanes
used and by the number of cables installed, as shown in the following table:
Maximum Line Rate (kHz) (1 sensor line output, 8 bit)
Camera Model
One Fiber Optic Cable
Two Fiber Optic Cables
One AOC cable
HL-FM-08K30H-00-R
140
280
NA
HL-HM-16K30H-00-R
NA
NA
300
Minimum Line Rate
The minimum line rate for all camera models is 300 Hz.
Scan Direction
See the section Camera Control Category in Appendix A for GenICam features associated with this
section and how to use them
Related Feature: sensorScanDirectionSource, sensorScanDirection
A TDI camera model requires the user to indicate to the camera the direction of travel of the object
being imaged.
The source of the scan direction is set using the sensorScanDirectionSource feature. The options
are: Internal, Line 2 (pin 6 on the GPIO connector), or the rotary encoder feature (using pin 5 and
pin 6 of the GPIO connector, only available when TriggerSource is “RotaryEncoder” and
rotaryEncoderOutputMode is set to “Motion”).
When set to internal, use the sensorScanDirection feature to set the direction.
It is important that the user do a flatfield and saves it for both scan directions if using both
directions.
Direction Change Time
The direction change time between forward and revers is < 1 ms.
Summary of Contents for Linea HS HL-FM-08K30H-00-R
Page 5: ...The Linea HS Monochrome Cameras 5 DECLARATION OF CONFORMITY 73 DOCUMENT REVISION HISTORY 74 ...
Page 15: ...The Linea HS Monochrome Cameras 15 Figure 4 HL HM 16K30H 00 R Mechanical Drawing ...
Page 26: ...26 Camera Performance and Features Figure 7 Image with incorrect scan direction ...
Page 73: ...Declaration of Conformity 73 Declaration of Conformity ...