92
•
Appendix A: GenICam Commands
Linea HS Series Camera User's Manual
Display Name
Feature
Description
View
Refresh BIST
deviceBIST
Command to perform an internal test which will determine
the device status. (W)
Beginner
DFNC
LED Color
deviceLEDColorControl
Select the mode for the LED
Beginner
DFNC
Off
Off Off
Red
Red BIST error.
Green
Green Operational.
Waiting for EXSYNC
Fast_Green 4 Hz Green.
Thermal Shutdown
Medium_Red 2 Hz Red.
Looking for link
Slow_Green 1 Hz Green.
Busy
Medium_Orange 2 Hz Orange.
Temperature
DeviceTemperature
Displays the internal operating temperature of the camera, in
Celsius. (RO)
Beginner
DFNC
Refresh
Temperature
refreshTemperature
Press to update
DeviceTemperature
.
Beginner
DFNC
Input Voltage
deviceInputVoltage
Displays the input voltage to the camera at the power
connector (RO)
Beginner
DFNC
Refresh Voltage
refreshVoltage
Press to update
deviceInputVoltage
.
Beginner
DFNC
Power-on User Set
UserSetDefaultSelector
Selects the camera configuration set to load and make active
on camera power-up or reset. The camera configuration sets
are stored in camera non-volatile memory. (RW)
Beginner
Factory Set
Factory Load factory default feature settings
UserSet1
UserSet1
Select the user defined configuration UserSet 1 as the Power-
up Configuration.
UserSet2
UserSet2 Select the user defined configuration UserSet 2 as the Power-
up Configuration
UserSet3
UserSet3 Select the user defined configuration UserSet 3 as the Power-
up Configuration
UserSet4
UserSet4 Select the user defined configuration UserSet 4 as the Power-
up Configuration.
UserSet5
UserSet5 Select the user defined configuration UserSet 5 as the Power-
up Configuration.
UserSet6
UserSet6 Select the user defined configuration UserSet 6 as the Power-
up Configuration.
UserSet7
UserSet7 Select the user defined configuration UserSet 7 as the Power-
up Configuration.
UserSet8
UserSet8 Select the user defined configuration UserSet 8 as the Power-
up Configuration.
UserSet9
UserSet9 Select the user defined configuration UserSet 9 as the Power-
up Configuration.
UserSet10
UserSet10 Select the user defined configuration UserSet 10 as the
Power-up Configuration.
UserSet11
UserSet11 Select the user defined configuration UserSet 11 as the
Power-up Configuration.
UserSet12
UserSet12 Select the user defined configuration UserSet 12 as the
Power-up Configuration.
UserSet13
UserSet13 Select the user defined configuration UserSet 13 as the
Power-up Configuration.