Linea HS Series Camera User's Manual
Appendix A: GenICam Commands
•
113
Upload File to Camera
•
Select the file by setting the FileSelector feature
•
Set the FileOpenMode to Write
•
Set the FileOperationSelector to Open
•
Open the file by setting FileOperationExecute to 1
This is a read-write feature - poll it every 100 ms until it returns 0 to indicate it has
completed
•
Read FileOperationStatus to confirm that the file opened correctly
A return value of 0 is success. Error codes are listed in the XML.
•
Read FileSize to get the maximum number of bytes allowed in the file
o
Abort and jump to Close if this is less the file size on the host
•
From FileAccessBuffer.Length you will know that maximum number of bytes that can be
written through FileAccessBuffer is 988.
•
For Offset = 0 While ((Offset < Host File Size) and (Status = 0)) Do
o
Set FileAccessOffset to Offset
o
Set FileAccessLength to min(Host File Size - Offset, FileAccessBuffer.Length), the
number of bytes to write
o
Read next FileAccessLength bytes from host file.
o
Write the bytes to FileAccessBuffer
o
Set the FileOperationSelector to Write
o
Write to the file by setting FileOperationExecute to 1 and poll until 0 and complete
o
Read FileOperationStatus to confirm the write worked
o
Read FileOperationResult to confirm the number of bytes written
•
Next Offset = number of bytes written
•
Set the FileOperationSelector to Close
•
Close the file by setting FileOperationExecute to 1 and poll until 0 and complete
•
Read FileOperationStatus to confirm the close worked
Download a List of Camera Parameters
For diagnostic purposes you may want to download a list of all the parameters and values
associated with the camera.
•
Go to File Access Control
•
Click on Settings
•
In the “Type” drop down box select “Miscellaneous.”
•
In the “File selector” drop down box select “CameraData.”
•
Hit “Download”
•
Save the text file and send the file to Teledyne DALSA customer support.