Piranha HS-S0-06K Camera User Manual
Teledyne DALSA
03-032-20213-01
9
Performance
Min Gain 0dB
Min Gain +10dB
Min Gain +20dB
Min
Typ
Max Min
Typ
Max Min
Typ
Max
Dynam ic Range
500
1024
(10 or 12-bit
op eration)
160
324
50
102
Rand om N oise
DN rm s
0.25
0.5
0.8
1.5
2.4
4.8
SEE nJ/ cm
2
0.2
0.065
0.02
N EE p J/ cm
2
0.2
0.2
0.24
Broad band
Resp onsivity
(DN / nJ/ cm
2)
1200
3800
12000
FPN DN p -p
w ith correction
2
PRN U DN p -p
w ith correction
2
Satu ration Ou tp u t
Am p litu d e DN
255
DC Offset w ith
correction DN
0.5
1.5
5
Test conditions unless otherwise noted:
TDI m od e of op eration. These sp ecification s are n ot gu aranteed for area m od e of
op eration.
Line Rate: 10 kH z.
N om inal Gain setting 0 d B.
Light Sou rce: Broad band Qu artz H alogen, 3250 k, w it h 700 nm IR cu toff filter
installed .
All sp ecification s are m easu red at 25 °C (front p late m easu rem ent).
All valu es are referenced at 8-bit.
1. Measured at the front plate. It is the user’s responsibility to insure that the operating
tem p eratu re d oes not exceed this range.