The digital system gain is set using the System Gain parameter, available on the Camera
Control tab.
Falcon System Gain – on Camera Control Tab
4.10.3
Subtracting Background
Serial Command
Purpose:
Use the background subtract command after performing flat
field correction if you want to improve your image in a low
contrast scene. It is useful for systems that process 8 bit data
but want to take advantage of the camera’s 10 bit digital
processing chain. You should try to make your darkest pixel in
the scene equal to zero.
Syntax:
ssb
t i
Syntax Elements:
t
Tap selection. This is always set to
0
(all taps).
i
Subtracted value in a range in DN from
0
to
511
.
Notes:
When subtracting a digital value from the digital video signal the
output can no longer reach its maximum. Use the
ssg
command
to correct for this where:
ssg
value
=
max
output
value
max
output
value
‐
ssb
value
Related Commands:
ssg
Example
ssb 0 25
DALSA