Falcon 1.4M100 Camera Manual
49
CamExpert Parameter
The pixel coefficients are enabled using the Frame Rate (Hz) parameter available through
the Camera Control tab. This parameter enables both FPN and PRNU coefficients.
Enable Flat Field Correction – on Camera Control Tab
4.9.4
Selecting the Calibration Sample Size
Serial Command
Setting the Number of Frames to Sample
Purpose:
Sets the number of frames to sample when performing pixel
coefficient calculations. Higher values cause calibration to take
longer but provide the most accurate results.
Syntax:
css
i
Syntax Elements:
i
Number of frames to sample. Allowable values are
32
(default),
64
,
128
,
256
,
512
, or
1024
.
Notes:
To return the current setting, use the
gcp
command.
Example:
css 1024
DALSA