52
•
Appendix A: GenICam Commands
Camera Control Category
The camera control category, as shown by CamExpert, groups control parameters such as line rate,
exposure time, scan direction, and gain.
Figure 21: Camera Control Panel
Camera Control Feature Descriptions
Display Name
Feature
Description
View
Device Scan
Type
DeviceScanType
Used to set the camera scanning mode.
Only standard line scan mode is
available.
Beginner
Linescan
Linescan Linescan sensor.
Color Type
RGB or
RGB+NIR
sensorColorType
Used to set the sensor color type mode.
Beginner
DFNC
CFA_BGR Color BGR.
Internal Line
Rate
AcquisitionLineRate
Specifies the camera internal line rate, in
Hz when Trigger mode set to internal.
Note that any user entered value is
automatically adjusted to a valid camera
value.
If necessary, the exposure time will be
decreased to fit within the line time.
Beginner
Measured Line
Rate
measureLineRate
Specifies the line rate provided to the
camera by either internal or external
source (RO)
Beginner
DFNC
Refresh
Measured Line
Rate
refreshMeasureLineRate
Press to show the current line rate
provided to the camera by either internal
or external sources
Beginner
DFNC
Exposure Mode
ExposureMode
Sets the operation mode for the camera’s
exposure
Beginner
Timed
Timed
The exposure duration time is set using
the Exposure Time feature and the
exposure starts with a LineStart event.