14.3 

Licenses

The 

License

 dialogue allows you to activate possible extra features.

For information about available extra features contact the Dallmeier Support.
For purchasing license codes, contact the Dallmeier Sales Department.

 

Open the 

License

 dialogue via 

Service

 > 

License ...

.

Fig. 14-3 

 

Enter the 

License code

.

 

Confirm with 

oK

.

14.4 

Event Log

The device logs IP addresses of applications that temporarily blocked certain resources 

of the device in a log file. The list of IP addresses is displayed in the 

event log

 dialogue.

 

Open the 

event log

 dialogue via 

Service

 > 

event log …

.

Fig. 14-4 

Summary of Contents for DDF4010HDV

Page 1: ...High end IP Network Dome Camera Full High Definition 1080p 10 Optical Zoom Auto focus Day Night Vandal resistant DDF4010HDV Installation and Configuration Rev 2 0 4 2013 09 09 English...

Page 2: ...ks or registered trademarks of the following owners Adobe and Flash of Adobe Systems Incorporated headquartered in San Jos California USA AMD and AMD Athlon of Advanced Micro Devices Inc headquartered...

Page 3: ...Outdoor 13 4 4 Operation 13 5 Views and Connection Assignment 14 5 1 In ceiling Mount Variant 14 5 2 Surface Mount Variant 16 5 3 Weather proof Variant 19 6 Installation and Commissioning 20 6 1 In c...

Page 4: ...1 Global 52 10 2 2 Image Optimization 54 10 2 3 White Balance 55 10 2 4 Day Night 56 10 3 Encoder Settings 57 10 3 1 Encoder 1 57 10 3 2 Encoder 2 60 10 3 3 Audio In 60 11 Event Management 61 11 1 DaV...

Page 5: ...Recovery 91 14 5 2 2 Configuration Transfer to Several Devices 92 14 6 Info 93 15 Image Transmission 94 15 1 Web Browser 94 15 2 RTSP Application 94 16 Maintenance 96 17 Pin Assignment 97 17 1 Termina...

Page 6: ...s the com plete product names will be mentioned Pictures in this document may differ from the actual product 1 2 Documents Commissioning The document entitled Commissioning contains the most important...

Page 7: ...in minor or moderate injury Notice NOTICE indicates practices for preventing property damage incorrect configurations or faulty operations For reasons of clarity and readability various text formattin...

Page 8: ...s and data loss and may result in the loss of warranty Modifications Do not make any modifications to the hardware or software that have not been tested and approved by Dallmeier Inappropriate modific...

Page 9: ...se malfunctions and damages The units may not be moved while in operation Foreign Bodies If objects or liquids get into the units immediately disconnect them from the power supply pull out the power p...

Page 10: ...onal improper transpor tation The goods should only be shipped in their original packaging If the original packaging is no longer available ensure that the packaging used sufficiently protects the uni...

Page 11: ...neous Dual Streaming video compression resolutions frame and bit rates of each stream independently adjustable Motion detection3 with selectable sensitivity Alarm notification via DaVid4 Protocol e ma...

Page 12: ...the contract shall apply 3 6 Approvals Certifications The following approvals certifications were valid for all devices described in this document at the time of this document s compilation CE FCC UL...

Page 13: ...fan and heater of the weather proof housing must be separately sup plied with an additional power supply unit 24V AC max 3A 4 3 Outdoor For outdoor installations always use the respective weather proo...

Page 14: ...Assignment 5 1 In ceiling Mount Variant M6 screw eye bolt Ceiling clamp Trim ring with bubble Housing Terminal area Lens Ceiling clamp Housing screw T20 Torx Fig 5 1 Ceiling clamp M6 screw eye bolt Le...

Page 15: ...eier com 15 M4 locking screw ceiling clamp Thread for housing screw USB SD port Video preview output 3 5mm phone jack M4 locking screw ceiling clamp Fig 5 3 3 axis mount pan tilt rotation WIDE button...

Page 16: ...read for housing screw Housing base Slot for spring clip 1 Securing screw spring clip 2 Video preview output 3 5mm phone jack USB SD port Housing with bubble Housing screw T20 Torx Lens Plug in module...

Page 17: ...ousing screw Thread for housing screw Mounting hole for 4mm screw Thread for PG16 cable gland Slot for spring clip 2 Terminal area Fig 5 6 Securing screw spring clip 1 Securing screw spring clip 1 Plu...

Page 18: ...DDF4010HDV www dallmeier com 18 Plug in module Securing screw spring clip 2 Securing screw spring clip 1 Spring clip 1 3 axis mount pan tilt rotation WIDE button TELE button Spring clip 2 Fig 5 8...

Page 19: ...P In 2 Brown GND I O Pink GP In 1 Blue GND I O Red GP OUT Ethernet RJ45 8 1 Green TRS Audio OUT 3 5mm stereo Pink TRS Audio IN 3 5mm stereo Fig 5 9 Note that the built in heater fan of the weather pro...

Page 20: ...or drywall hollow wall type plaster Electric shock hazard Danger of death or serious injury Always disconnect the PoE switch or the separate power supply unit from the mains socket pull out the power...

Page 21: ...the trim ring Suspended ceiling 169mm M6 screw eye bolt Ceiling clamp Ceiling clamp Trim ring with bubble Housing screw T20 Torx Fig 6 1 Step 2 Fig 6 2 Screw a ceiling hook on the supporting structure...

Page 22: ...g hook Suspended ceiling Ceiling clamp Ceiling clamp Terminal area Fig 6 2 Step 3 Tighten the M4 locking screw Fig 5 3 of both ceiling clamps with a Phillips screw driver until the housing is fixed Fi...

Page 23: ...monitor to the video preview output Fig 5 3 Align the camera with your scene using the 3 axis mount and set the focal length with the TELE WIDE buttons Fig 5 4 The Little Man symbol on the lens side...

Page 24: ...her Mark the drill holes on the ceiling wall using the 3 pre drilled mounting holes of the housing base Fig 5 6 as a template At the marked locations drill holes fitting the screws anchors to be used...

Page 25: ...2 Slot for spring clip 2 Fig 6 7 If PoE Power over Ethernet is not available first connect the camera to a suitable power supply unit and then connect the power supply unit to the mains socket If nec...

Page 26: ...ernet Explorer latest version Software Adobe Flash Player latest version JavaScript enabled Microsoft ActiveX enabled ActiveX based Dallmeier control latest version Note that a more powerful PC is req...

Page 27: ...al user interface GUI of the live mode is displayed F E J H B I G A C D Fig 7 1 Live mode with adjustable live video display size and camera control A Hide show title bar B Switch between live and con...

Page 28: ...Button Minimize Maximize To move a panel left click the panel title bar 1 and then drag the panel to the desired position while holding down the left mouse button Release the mouse button to drop the...

Page 29: ...ission Control Protocol TCP To receive the data packets the port 30000 for the DaVid Protocol5 and port 80 for the Hypertext Transfer Protocol HTTP must be open Note that during the data transmission...

Page 30: ...d configuration mode C IP address of device D Log out of configuration mode E Disable enable live video display F Live video G Configuration menu H Connection method UDP TCP I Audio On Off audio encod...

Page 31: ...ommon settings User interface Fig 8 1 Set the Language Deactivate the Show live video ActiveX in WebConfig checkbox if network bottle necks occur or your system is overloaded Confirm with OK 8 2 Syste...

Page 32: ...must always be accessible via the network Select the Time server tab Fig 8 4 Enter the IP address or the host name of the time server Activate the Use time server checkbox to enable the UTC time serv...

Page 33: ...better readability Confirm with OK 8 4 User Management The configuration of the device must be preceded by a successful authentication as an authorized user or user group The user management allows f...

Page 34: ...e changed Note that the factory default password of the local user group Group 1 admin is 3 the factory default password of the local user group Group 1 admin must be changed for security reasons the...

Page 35: ...gin mode individual local users can be assigned to the three local user groups Define New User Ensure that the Login mode is set to User login Open the User groups dialogue via Common settings User ma...

Page 36: ...he following LDAP settings should only be performed by an administrator with advanced skills in LDAP technology In order to be able to set the respective group policies rights on the LDAP client this...

Page 37: ...ice must be configured accordingly In this respect note the following steps and descriptions Ensure that the Login mode is set to LDAP login Select the LDAP options tab Fig 8 10 For the correct access...

Page 38: ...e settings on the LDAP client can only be saved if the query has been successful re turns an internal result Click Test Fig 8 11 Enter the LDAP user name and the corresponding LDAP user password of an...

Page 39: ...ted or denied access to certain types of live images and or live audio Note that the rights of group 1 administrator can not be restricted certain permission levels can not be set for all rights certa...

Page 40: ...displayed The settings can be changed The function can be used allow read only The dialogue will be displayed The settings can not be changed deny The dialogue will not be displayed The settings can n...

Page 41: ...Network settings dialogue via Network Basic settings Fig 9 1 Network settings and MAC address Default Factory Settings Connection type automatic Bandwidth limit none Get IP settings from DHCP deactiv...

Page 42: ...hosts file on your local computer The Host name or more appropriately the short host name specifies the name of the machine itself e g myhostname The Domain name is usually the network domain within...

Page 43: ...ork settings automatically proceed as follows Ensure that an active DHCP server is available in your local area network LAN Activate the Get IP settings from DHCP checkbox If required configure the av...

Page 44: ...put Select the transfer protocol format and method from the drop down list Mode Depending on the selected transfer method enter the Multicast IP address or the Destination IP address Enter the port nu...

Page 45: ...ansfer method defines the distribution of the data throughout the network Multicast The data packets are provided with the specified IP multicast address and port number and transferred to a group of...

Page 46: ...r multicast TTL 64 for unicast 9 2 1 4 RTCP The Real time Transport Control Protocol RTCP is an extension to the Real time Trans port Protocol RTP and is used for i a the transmission of periodic stat...

Page 47: ...dio source must be identical with the Multicast IP address registered in the audio client of the camera For descriptions about the different transfer methods unicast and multicast see section Transfer...

Page 48: ...mission via UDP packet losses e g lack of individual images can oc cur Lost packets will not be sent again Usually UDP packets that come from outside internet into the local area network are blocked b...

Page 49: ...eiver client no longer accepts additional data the camera can no longer send further image data The result is a so called data backlog in the camera In order to prevent a loss of images the yet unsent...

Page 50: ...correct video signal transmission the device must be set to the appropriate video standard for your country HD 25 50 fps for PAL countries HD 30 60 fps for NTSC countries Open the Video standard dial...

Page 51: ...e image sensor and the adjustment of the image processing parameters to the local situation Open the Sensor settings dialogue via Video Sensor Fig 10 2 Note the explanations below Set the relevant opt...

Page 52: ...y Variable iris auto gain and shutter speed Manual Variable shutter speed iris and gain Shutter Adjustable with shutter priority and manual exposure control Iris Adjustable with iris priority and manu...

Page 53: ...adjusts the focus position by measuring the contrast of the centre im age area sufficient illumination and subject contrast for central measurement area are required Manual manual focusing Recommended...

Page 54: ...mid tones the distribution of light between black and white and thus the image contrast However note that the effect of the gamma setting always depends on the individual display device Normal Typica...

Page 55: ...Preset for indoor scenes with colour temperature of 3200K Outdoor Preset for outdoor scenes with colour temperature of 5800K One Push The One Push white balance value is a fixed measured value which i...

Page 56: ...ly enhances the sensor s sensitivity for near infrared light Depending on the amount of visible light the IR cut filter is automatically engaged ICR OFF and the camera switches back to day mode again...

Page 57: ...der 1 Open the Encoder settings dialogue via Video Encoder settings The Encoder 1 tab is displayed Fig 10 7 Note the explanations below Select the encoding standard from the drop down list Encoder mod...

Page 58: ...e Low image compression Large data volume High image quality High bandwidth and hard disk space usage Usually most requirements in surveillance applications are met with a bit rate between 4 and 6Mbps...

Page 59: ...ing or accessing a stream The GOP sequence ends before the next I Frame At a later stage the visible single frames are generated at the decoder using the indi vidual GOPs The GOP size 1 I Frames only...

Page 60: ...processing encoding options of the analogue audio signal coming from the built in Audio IN port Select the Audio tab Fig 10 9 Select the format and bit rate with which the incoming analogue audio sig...

Page 61: ...installed Contact OUT interface Click Event management in the configuration menu If no event handler has been set yet only the New item is displayed Click Event management New The configuration menu...

Page 62: ...ends event triggered notifications to an alarm host using the DaVid Protocol For the evaluation of the event messages a DaVid Protocol capable software e g PGuard advance8 must be running on the respe...

Page 63: ...63 Select the Trigger tab Fig 11 3 Contact status Status change of Contact IN 1 2 or 3 Select all relevant triggers which are supposed to be sent out as event messages by activating the related checkb...

Page 64: ...mail recipients Depending on the used SMTP server and its configuration any name can be used for the sender or a SMTP authentication is required Fig 11 4 If necessary enter the User name and the Passw...

Page 65: ...the Add image as attachment checkbox to attach the current JPEG image captured exactly at the moment the event is triggered to the e mail Select an encoder from the drop down list Image source to def...

Page 66: ...NO Normally Open has been closed Contact 2 opened Contact IN 2 NC Normally Closed has been opened Contact 3 closed Contact IN 3 NO Normally Open has been closed Contact 3 opened Contact IN 3 NC Norma...

Page 67: ...that read and write permissions are set for the specified directory and enough free disk space is available Enter the name under which the JPEG images are to be saved into the Filename field Select t...

Page 68: ...source to define the source of the JPEG images The used encoder must be enabled Encoder 2 is disabled by default and configured for MJPEG encoding see section Encoder Settings on page 57 Click Test t...

Page 69: ...3 opened Contact IN 3 NC Normally Closed has been opened Contact status Status change of Contact IN 1 2 or 3 Interval Duration sec This trigger option allows you to configure the automatic FTP upload...

Page 70: ...c status change of the hardware installed Contact OUT interface Note the section Contact OUT on page 83 and the chapter Pin Assignment on page 97 Fig 11 8 Select the relevant Contact OUT interface whi...

Page 71: ...1 Select the Trigger tab Fig 11 9 Remote control Remote status change of Contact OUT via DaVid Protocol e g SMAVIA Viewing Client see below Select all relevant triggers by activating the related check...

Page 72: ...der tab in the Configuration window Select the relevant camera in the Recorder list Click the Edit button Select the Relay tab in the Edit recorder window Activate the Request relay status checkbox If...

Page 73: ...entire year if no exceptions are set 11 5 1 Week Timer Click Scheduler The Week timer tab is displayed Fig 11 10 Light gray areas in the week timer represent active periods During active periods the m...

Page 74: ...sages are sent out and no alarm actions are executed Confirm with OK if you do not want to make any additional settings Delete Inactive Periods Click active In the week timer click and hold the left m...

Page 75: ...eptions can be defined Note that exceptions will overwrite the settings of the entire relevant day in the week timer Select the Exceptions tab Fig 11 12 Click New The Calendar is displayed Fig 11 13 S...

Page 76: ...left mouse button and draw a rectangle over a rel evant period Release the mouse button Repeat the last two steps until all relevant active periods are selected Fig 11 15 Light gray areas in the time...

Page 77: ...ions at least 15 minutes between active periods If the exception settings are to apply to other days as well they can be can copied to another date see below Confirm with OK if you do not want to make...

Page 78: ...DDF4010HDV www dallmeier com 78 Fig 11 17 To delete exceptions select the relevant date in the exceptions list and click Delete Confirm with OK if you do not want to make any additional settings...

Page 79: ...ings The copy function allows you to copy saved event settings to other event handlers Click Event management in the configuration menu Click on a saved event handler item in the configuration menu Th...

Page 80: ...The configuration menu is expanded with the name of the copied event handler with the addition 1 represents copy 1 and the related dialogue of the copy is displayed Fig 11 19 Customize the relevant s...

Page 81: ...er proceed as follows Click Event management in the configuration menu In the configuration menu click on an event handler you want to delete The related dialogue is displayed Fig 11 20 Click Delete T...

Page 82: ...12 1 Default Factory Settings Mode RS485 Baud 9600 Bits 8 Parity none Stop Bits 1 Protocol none Select Crosslink from the drop down list Function to enable the control signal loop through connection S...

Page 83: ...Interfaces Contact Out Fig 12 2 Timer Select Timer On if you want to limit the duration for which a Contact OUT status change remains active In the Time sec field enter the duration time in seconds f...

Page 84: ...externally transferred data can be filtered before embedding The filtering selection only takes effect on externally sent data Open the Data display Filter dialogue via Interfaces Data display Filter...

Page 85: ...d size resolution of the actual screen depend on the used client Specified coordinates are automatically converted rescaled for the screen resolu tion of the used client e g Full HD and matched to its...

Page 86: ...ositioned by drag drop Fig 12 5 The display area can be resized by dragging its yellow corner in the bottom right Fig 12 6 An exact positioning and resizing is possible by using the corresponding inpu...

Page 87: ...3 1 Click Zoom to zoom in Tele Click Zoom to zoom out Wide Click Iris to open the iris Click Iris to close the iris Click Focus for far focusing Click Focus for near focusing Note that manual focusing...

Page 88: ...or network elements cameras recorders routers switches print ers etc with a Network Management System NMS MIB files allow for the unambiguous assignment of network elements within the Manage ment Info...

Page 89: ...ng license codes contact the Dallmeier Sales Department Open the License dialogue via Service License Fig 14 3 Enter the License code Confirm with OK 14 4 Event Log The device logs IP addresses of app...

Page 90: ...e If the configuration file is to be transferred to several devices the Network settings must not be exported Open the Configuration file management dialogue via Service Configuration file Download Fi...

Page 91: ...tically configure several devices in terms of certain configuration groups 14 5 2 1 Configuration Recovery To recover the configuration of an individual device the connection to the device must be est...

Page 92: ...ver every IP address in a LAN must be unique this would cause massive problems in the network Notice Ensure that the configuration of the Network settings is not transferred to several devices To be a...

Page 93: ...Click Info in the configuration menu Fig 14 8 The following information is displayed Device type Software version Version number of the encoder ONVIF version Version number of the Linux Kernel Serial...

Page 94: ...used encoder must be enabled the JPEG live access right permission must be enabled Use the following URL request for the various encoders Encoder 1 http IP address of the device live image0 jpg Encod...

Page 95: ...er 1 and 2 can be requested by two applications simultaneously This allows you to realize a Dual Streaming functionality two streams with different quality The required bandwidth proportionally increa...

Page 96: ...ollowing notes Notice Damage to the surface of the device Clean the housings outside with a soft dry and antistatic cloth Do not use detergents Clean the plastic bubble acrylic glass with water and so...

Page 97: ...AC power supply unit However always beware not to use both power sources simultaneously Power 24V AC Weidm ller male connector SL 3 50 02 90G mating connector Weidm ller BL 3 50 02 180 SN Fig 17 2 In...

Page 98: ...k front view 1 8 Fig 17 3 10BASE T 100BASE TX PoE PoE Class 0 IEEE 802 3af Audio out in 3 5mm phone jack GND R L Fig 17 4 Green Line Out stereo Pink Line In stereo L Left channel L Left channel R Righ...

Page 99: ...signment 1 Rx 2 Rx 3 Tx 4 Tx 5 GP Out 6 GND I O 7 GP In 1 8 GND I O 9 GP In 2 10 GND I O 11 GP In 3 12 GND I O Inputs To activate the input connect the signal to GND I O Output 5V DC max 10mA to GND I...

Page 100: ...DDF4010HDV www dallmeier com 100 17 2 Plug in Module Video preview output 3 5mm phone jack Fig 17 6 Video preview output 3 5mm phone jack GND Not used Signal Fig 17 7...

Page 101: ...ways use a UL certified Limited Power Source LPS Class 2 power supply unit Blue Power Fan Heater Brown 24V AC max 3A Black Power Camera Black White 24V AC Green White RS485 Rx Green RS485 Rx Yellow Wh...

Page 102: ...rial interface 1 RS485 full duplex half duplex Local video memory USB SD port integrated adapter for SDHC card separately available Ethernet 1 RJ45 10BASE T 100BASE TX PoE Programming interface Open A...

Page 103: ...iant black housing white cover ring Surface mount variant white Weather proof variant white Adjustment 3 axis Bubble Clear with black inner liner for discrete surveillance Environmental Conditions Ope...

Page 104: ...Drawings The following technical drawings were valid at the time of this document s compilation Visit www dallmeier com for possible updates 19 1 In ceiling Mount Variant 168mm 6 61 25 mm 89 mm 3 50 1...

Page 105: ...DDF4010HDV www dallmeier com 105 19 2 Surface Mount Variant 186mm 7 32 94 mm 3 70 67 mm 2 64 121mm 4 76 145mm 5 71 50 mm 1 97 Fig 19 2...

Page 106: ...DDF4010HDV www dallmeier com 106 19 3 Weather proof Variant 258 50mm 10 18 167mm 6 57 86 50 mm 3 41 184 50 mm 7 26 59 mm 2 32 147mm 5 79 Fig 19 3...

Page 107: ...restriction of certain haz ardous substances in electrical and electronic equipment The following company is responsible for this declaration Dallmeier electronic GmbH Co KG Cranachweg 1 93051 Regens...