Alarm
Description and Tips
Severity
Reboot to Recovery Console
failed
Check FPGA status on hosts and
remotes. Reduce system load and try
again.
CRITICAL
RF Module Activating Error
Error received when activating RF
module.
Attempt to recover by deactivating and
reactivating module.
MAJOR
RF Module Being Serviced
RF module is physically present but
regular communication is not possible
due to servicing.
Wait for software upgrade to complete
for up to 5 or 10 minutes.
An interruption of software upgrade due
to power loss may cause RF module to
remain in this state.
Remote servicing of unit will put module
in this state.
MAJOR
RF Module Communications
Failure
RF module was detected but
communication to the module has failed.
MAJOR
RF Module Deactivated Itself
RF Module has deactivated itself for an
unknown reason.
Attempt to recover by reactivating
module.
Power to RF module may have been
interrupted due to high load.
RF module may have been reset.
CRITICAL
RF Module is Missing
An RF module has failed or has been
intentionally removed.
Replace with a functional RF module.
To clear this alarm, either replace a
module in this slot, or mark the slot as
Unavailable.
CRITICAL
RF Module Not Ready
Wait for boot process to complete and
PLL to lock.
MAJOR
RF Path Deactivated by User
The user has intentionally deactivated
the RF path
Reactivate the RF path as needed
To permanently deactivate the RF path
without alarm, set the slot to
Unavailable.
MINOR