Matrix PS System Installation and Commissioning Guide
|
233
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
Alarm
Description and Tips
Severity
Output Path ALC Range Exceeded
The output path power has exceeded
safe levels and consequently the RF path
has been deactivated.
The input path power may also be high
or there has been a transient high input
power.
The system gain may be higher than
expected.
Once the cause has been addressed
reactivate the RF path.
CRITICAL
Output Path High Power
The output path power has exceeded
safe levels and consequently the RF path
has been deactivated.
The input path power may also be high
or there has been a transient high input
power.
The system gain may be higher than
expected.
Once the cause has been addressed
reactivate the RF path.
CRITICAL
Output Path High VSWR
The reflected power (VSWR) threshold is
exceeded. Ensure that the load on the
antenna port is properly matched to 50
ohms.
Check for damaged or disconnected
cables or antennas.
MINOR
Output Path LO Out of Lock
Module has been deactivated.
Ensure unit is operating within valid
temperature range.
Attempt to recover the LO lock by
disabling and re-enabling module.
CRITICAL
Output Path Low RF Module Gain
An element in the path is not providing
sufficient RF gain
This may be the RF module or mixed
signal portions of the unit
Ensure DC power is available by checking
the input voltage reported by module
If it is field replaceable try an alternate
module
MAJOR
Output RF Path Low Gain
RF path gain is lower than expected.
RF levels may be out of range.
Module may be damaged.
MAJOR
POE Initialization Failure
Operation is possible except for use of
POE.
Alternate power sources for POE devices
will be required.
MINOR