Matrix PS System Installation and Commissioning Guide
|
131
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
Figure 12-4: Redundant Controllers with Ethernet Switches – More than Six Host Units
12.7.2
Turning On Redundant Controllers after Installation
For information on installing Matrix Console hardware, see
When turning on redundant controllers, start the Secondary controller first, followed by
the Primary controller.
To turn on redundant controllers:
1. Make sure both system controllers are disconnected from the external and internal
Matrix IP networks. All Ethernet cables should be unplugged from the units.
2. Make sure controllers are labeled as Primary and Secondary. Units are usually pre-
provisioned and labeled at the factory.
3. Turn on the Secondary controller first by plugging the AC cable into an AC power
source, followed by the Primary controller. There is no power switch. The unit is on
when the LED on the front panel is green.
4. Connect Ethernet cables to both system controllers, following the network plan
provided by your DAS integrator. See also
Matrix Console PS Installation
5. Verify that you can log into both Primary and Secondary controller and display the
EMS.