background image

DLM 

Single Channel

BUS

Device Manual    

EASY-BUS

                       

FW 1.2

 

Made in Italy

Rev. 2018-07-23

pag. 1/11

 

FEATURES

• BUS+FADER+DRIVER
• DC input: DC 12-24-48 Vdc or 12-24Vdc
• BUS Command: 
- DALI
- RDM
• MULTI INPUT – Analogic Automatic Detection of the Local Command:

- Normally Open Push-Button 
- 0-10V
- 1-10V

    - Potentiometer 10KOhm
• PUSH MENU’ – Possibility to set:

- Minimum value of dimming
- Fade In
- Fade Out

• Constant voltage variant to Common Anode applications
• Voltage outputs for R-L-C loads, DLM1248-1CV-DALI or DMX
• Voltage outputs for R loads, DLM1224-1CV-DALI or DMX
• Memory function 
• Adjusting the brightness of White light or monochromatic color
• Adjusting the brightness up to completed off
• Soft start and soft stop
• Optimized output curve
• Typical efficiency > 95%
• 100% Functional test – 5 Years warranty

    CONSTANT VOLTAGE VARIANTS 

      Application: Dimmer

 

CODE

Input Voltage

Output

Channels

BUS Command

Analogic Auto Detection

DLM1248-1CV-DALI 12-48V DC

1 x 6,5A

DALI 

N° 1 N.O. Push Button
N° 1 analog signal 0-10V
N° 1 analog signal 1-10V
N° 1 potentiometer 10KOhm

DLM1224-1CV-DALI 12-24V DC

1 x 10A 

DALI 

DLM1248-1CV-DMX 12-48V DC

1 x 6,5A

DMX 

N° 1 N.O. Push Button
N° 1 analog signal 0-10V
N° 1 analog signal 1-10V
N° 1 potentiometer 10KOhm

DLM1224-1CV-DMX 12-24V DC

1 x 10A 

DMX 

   The LED Dimmer is produced by default with:

- Analog Automatic Detection of local command set as N.O. Push Button
- Dimming minimum level at 1%

     

PROTECTIONS

DLM1248-1CV-DALI/DMX

DLM1224-1CV-DALI/DMX

OTP

Over temperature protection (*)

OVP

Over voltage protection (**)

UVP

Under voltage protection (**)

RVP

Reverse polarity protection (**)

IFP

Input fuse protection (**)

SCP

Short circuit protection

OCP

Open circuit protection

CLP

Current limit protection

 (*) Thermal Protection on the output channel in case of high temperature. The thermal intervention is detected by transistor (> 150°C)
(**) Only control logic protection

DLM 1248 singolo canale BUS

 

LED DRIVERS

DALCNET S.r.l.

Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy 

Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy 

Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453 

VAT: IT-04023100235 

[email protected] www.dalcnet.com

N

 E

 W

              

                       

        P 

U

 

S

 

H

 

         

           

           

       M

 

E

 

N

 

U

 

Summary of Contents for DLM Series

Page 1: ...n N 1 analog signal 0 10V N 1 analog signal 1 10V N 1 potentiometer 10KOhm DLM1224 1CV DALI 12 24V DC 1 x 10A 1 DALI DLM1248 1CV DMX 12 48V DC 1 x 6 5A 1 DMX N 1 N O Push Button N 1 analog signal 0 10V N 1 analog signal 1 10V N 1 potentiometer 10KOhm DLM1224 1CV DMX 12 24V DC 1 x 10A 1 DMX The LED Dimmer is produced by default with Analog Automatic Detection of local command set as N O Push Button...

Page 2: ... DLM1248 1CV DALI or DMX Variant DLM1224 1CV DALI or DMX Variant Constant voltage Constant voltage Supply voltage min 10 8 Vdc max 52 8 Vdc min 10 8 Vdc max 26 4 Vdc Output voltage Vin Vin Output current 6 5A 40 C 1 10A 40 C 1 Absorbed nominal power 1 12V 78 W 120 W 24V 156 W 240 W 48V 312 W Power loss in stand by mode 500mW 500mW Type of Load R L C R Thermal shutdown 2 150 C D PWM dimming frequen...

Page 3: ...8 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 0444 1836680 1867452 Fax 39 0444 1867453 VAT IT 04023100235 info dalcnet com www dalcnet com SWITCHING SUPPLY Vout L N 230V DALI DC IN N O PUSH BUTTON DALI In 12 48V Out max 8A DC IN OUT DALI DA DA INPUT COM 0 10V COMMAND DMX In 12 48V Out...

Page 4: ... a protection against over current between the power supply and the device Command The length of the connection cables between the local commands N O Push button 0 10 V 1 10 V Potentiometer or other and the product must be less than 10m the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV It is suggested to use double insulated shielde...

Page 5: ...nd AUTOMATIC DETECTION OF THE 0 1 10V POTENTIOMETER COMMAND The automatic recognition of analog signal 0 1 10V or potentiometer starts as soon as a 0 1 10V value between 3V and 7V is sent out or setting the potentiometer with a value included from 30 and 70 0 10V COMMAND 1 10V COMMEND POTENTIOMETER AUTOMATIC DETECTION OF THE N O PUSH BUTTON COMMAND The N O push button is identified automatically a...

Page 6: ... 2 POWER ON RAMP FADE IN Every single click make it changing the power on ramp There are five levels of power on ramp FADE IN instantaneous 1 second 2 seconds 3 seconds 6 seconds After setting the FADE IN press a long to confirm Three flashes confirm the storage and you can go to MENU 3 MENU 3 POWER OFF RAMP FADE OUT Every single click make it changing the power off ramp There are five levels of p...

Page 7: ...ol is active When the BUS is detected the control passes to the BUS In the absence of signal the control passes to local commands in the event of the button pressure ADDRESSING Simplified method One ballast connected at a time Random Address Allocation ADDRESSES MAP The intensity and the status ON OFF is controlled by a DALI controller Address Function Value 1 Dimmer Intensity 0 254 Intensity 0 25...

Page 8: ...ROUP 0 to 15 REMOVE FROM GROUP 0 to 15 STORE DTR AS SHORT ADDRESS ENABLE WRITE MEMORY QUERY STATUS 1 QUERY BALLAST QUERY LAMP FAILURE 1 QUERY LAMP POWER ON QUERY LIMIT ERROR QUERY RESET STATE QUERY MISSING SHORT ADDRESS QUERY VERSION NUMBER QUERY CONTENT DTR QUERY DEVICE TYPE 2 QUERY PHYSICAL MINIMUM LEVEL QUERY POWER FAILURE QUERY CONTENT DTR1 QUERY CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL...

Page 9: ...o change SEARCH ADDRESS FF FF FF FF FF FF RANDOM ADDRESS FF FF FF FF FF FF GROUP 0 7 0 0 GROUP 8 15 0 0 SCENE 0 15 MASK MASK STATUS INFORMATION 1 0 0 100 VERSION NUMBER 1 no change PHYSICAL MIN LEVEL 1 no change DLM 1248 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 0444 1836680 1867452...

Page 10: ...ntrol is active When the BUS is detected the control passes to the BUS In the absence of signal the control passes to local commands in the event of the button pressure ADDRESSING RDM Notice device addressing have to be carried out by a DMX RDM programmer CHANNEL MAPS The intensity and the status ON OFF is controlled by a DMX controller Channel Function Value 1 Dimmer Intensity 0 255 Intensity 0 2...

Page 11: ...RAMETER_DESCRIPTION BOOT_SOFTWARE_VERSION_ID DEVICE_INFO BOOT_SOFTWARE_VERSION_LABEL SOFTWARE_VERSION_LABEL DMX_PERSONALITY DMX_START_ADDRESS DMX_PERSONALITY_DESCRIPTION IDENTIFY_DEVICE SLOT_INFO SLOT_DESCRIPTION DEFAULT_SLOT_VALUE DLM 1248 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 ...

Reviews: