background image

DLM 

Single Channel

BUS

Device Manual    

EASY-BUS

                       

FW 1.2

 

Made in Italy

Rev. 2018-07-23

pag. 4/11

MECHANICAL DIMENSION

DLM1224 1CV BUS Variant

DLM1248 1CV BUS Variant

TECHNICAL NOTE

Installation:
• Installation and maintenance must be performed only by qualified personnel in compliance with current regulations.
• The product must be installed inside an electrical panel protected against overvoltages.
• The product must be installed in a vertical or horizontal position with the cover / label upwards or vertically; Other positions are not permitted. It is not
permitted to bottom-up position (with the cover / label down).
• Keep separated the circuits at 230V (LV) and the circuits not SELV from circuits to low voltage (SELV) and from any connection with this product. It is
absolutely forbidden to connect, for any reason whatsoever, directly or indirectly, the 230V mains voltage to the bus or to other parts of the circuit.

Power Supply:
• For the power supply use only a SELV power supplies with limited current, short circuit protection and the power must be dimensioned correctly. 
In case of using power supply with ground terminals, all points of the protective earth (PE = Protection Earth) must be connected to a valid and certified
protection earth.
• The connection cables between the power source "low voltage" and the product must be dimensioned correctly and they should be isolated from
every wiring or parts at voltage not SELV. Use double insulated cables.
• Dimension the power supply for the load connected to the device. If the power supply is oversized compared with the maximum absorbed current,
insert a protection against over-current between the power supply and the device. 

Command:
• The length of the connection cables between the local commands (N.O. Push button, 0-10 V, 1-10 V, Potentiometer or other) and the product must be
less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV.  It is suggested to
use double insulated shielded and twisted cables.
• The length and type of the connection cables at the BUS (DMX512, DALI or other) use cables as per specification of the respective protocols and
regulations and they should be isolated from every wiring or parts at voltage not SELV. It is suggested to use double insulated shielded and twisted
cables.
• All the product and the control signal connect at the bus (DMX512, DALI, Ethernet, or other) and at the local command (N.O. Push Button, 0-10V, 1-
10V, Potentiometer or other) must be SELV (the devices connected must be SELV or supply a SELV signal) 

 Outputs:
• The length of the connection cables between the product and the LED module must be less than 10m; the cables must be dimensioned correctly and
they should be isolated from every wiring or parts at voltage not SELV. It is suggested to use double insulated shielded and twisted cables.

DLM 1248 singolo canale BUS

 

LED DRIVERS

DALCNET S.r.l.

Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy 

Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy 

Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453 

VAT: IT-04023100235 

[email protected] www.dalcnet.com

B-B

 

Self-tapping screws countersunk head

d2.9x6.5 mm

Screws for pressed wood or chipboard

d2.5 mm for dowel fixing to wall

5,1

2,5

Ø

5

,1

57,2

4

2

,8

4

4

,4

57

,6

1,8

1

5

5,3

0,5

19

13,4

2,6

1,6

1

,1

R1

,3

7

,5

1,

1

2,6

7,

5

25

5,1

19,4

5,2

57,2

4

4,

4

4

2,

2

1,8

2,5

Ø

5,

1

2

,3

57

,6

7

Summary of Contents for DLM Series

Page 1: ...n N 1 analog signal 0 10V N 1 analog signal 1 10V N 1 potentiometer 10KOhm DLM1224 1CV DALI 12 24V DC 1 x 10A 1 DALI DLM1248 1CV DMX 12 48V DC 1 x 6 5A 1 DMX N 1 N O Push Button N 1 analog signal 0 10V N 1 analog signal 1 10V N 1 potentiometer 10KOhm DLM1224 1CV DMX 12 24V DC 1 x 10A 1 DMX The LED Dimmer is produced by default with Analog Automatic Detection of local command set as N O Push Button...

Page 2: ... DLM1248 1CV DALI or DMX Variant DLM1224 1CV DALI or DMX Variant Constant voltage Constant voltage Supply voltage min 10 8 Vdc max 52 8 Vdc min 10 8 Vdc max 26 4 Vdc Output voltage Vin Vin Output current 6 5A 40 C 1 10A 40 C 1 Absorbed nominal power 1 12V 78 W 120 W 24V 156 W 240 W 48V 312 W Power loss in stand by mode 500mW 500mW Type of Load R L C R Thermal shutdown 2 150 C D PWM dimming frequen...

Page 3: ...8 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 0444 1836680 1867452 Fax 39 0444 1867453 VAT IT 04023100235 info dalcnet com www dalcnet com SWITCHING SUPPLY Vout L N 230V DALI DC IN N O PUSH BUTTON DALI In 12 48V Out max 8A DC IN OUT DALI DA DA INPUT COM 0 10V COMMAND DMX In 12 48V Out...

Page 4: ... a protection against over current between the power supply and the device Command The length of the connection cables between the local commands N O Push button 0 10 V 1 10 V Potentiometer or other and the product must be less than 10m the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV It is suggested to use double insulated shielde...

Page 5: ...nd AUTOMATIC DETECTION OF THE 0 1 10V POTENTIOMETER COMMAND The automatic recognition of analog signal 0 1 10V or potentiometer starts as soon as a 0 1 10V value between 3V and 7V is sent out or setting the potentiometer with a value included from 30 and 70 0 10V COMMAND 1 10V COMMEND POTENTIOMETER AUTOMATIC DETECTION OF THE N O PUSH BUTTON COMMAND The N O push button is identified automatically a...

Page 6: ... 2 POWER ON RAMP FADE IN Every single click make it changing the power on ramp There are five levels of power on ramp FADE IN instantaneous 1 second 2 seconds 3 seconds 6 seconds After setting the FADE IN press a long to confirm Three flashes confirm the storage and you can go to MENU 3 MENU 3 POWER OFF RAMP FADE OUT Every single click make it changing the power off ramp There are five levels of p...

Page 7: ...ol is active When the BUS is detected the control passes to the BUS In the absence of signal the control passes to local commands in the event of the button pressure ADDRESSING Simplified method One ballast connected at a time Random Address Allocation ADDRESSES MAP The intensity and the status ON OFF is controlled by a DALI controller Address Function Value 1 Dimmer Intensity 0 254 Intensity 0 25...

Page 8: ...ROUP 0 to 15 REMOVE FROM GROUP 0 to 15 STORE DTR AS SHORT ADDRESS ENABLE WRITE MEMORY QUERY STATUS 1 QUERY BALLAST QUERY LAMP FAILURE 1 QUERY LAMP POWER ON QUERY LIMIT ERROR QUERY RESET STATE QUERY MISSING SHORT ADDRESS QUERY VERSION NUMBER QUERY CONTENT DTR QUERY DEVICE TYPE 2 QUERY PHYSICAL MINIMUM LEVEL QUERY POWER FAILURE QUERY CONTENT DTR1 QUERY CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL...

Page 9: ...o change SEARCH ADDRESS FF FF FF FF FF FF RANDOM ADDRESS FF FF FF FF FF FF GROUP 0 7 0 0 GROUP 8 15 0 0 SCENE 0 15 MASK MASK STATUS INFORMATION 1 0 0 100 VERSION NUMBER 1 no change PHYSICAL MIN LEVEL 1 no change DLM 1248 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 0444 1836680 1867452...

Page 10: ...ntrol is active When the BUS is detected the control passes to the BUS In the absence of signal the control passes to local commands in the event of the button pressure ADDRESSING RDM Notice device addressing have to be carried out by a DMX RDM programmer CHANNEL MAPS The intensity and the status ON OFF is controlled by a DMX controller Channel Function Value 1 Dimmer Intensity 0 255 Intensity 0 2...

Page 11: ...RAMETER_DESCRIPTION BOOT_SOFTWARE_VERSION_ID DEVICE_INFO BOOT_SOFTWARE_VERSION_LABEL SOFTWARE_VERSION_LABEL DMX_PERSONALITY DMX_START_ADDRESS DMX_PERSONALITY_DESCRIPTION IDENTIFY_DEVICE SLOT_INFO SLOT_DESCRIPTION DEFAULT_SLOT_VALUE DLM 1248 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 ...

Reviews: