2. TECHNICAL DESCRIPTION
The continuous fire cookers of DAL ZOTTO are suitable to cook on the grill and on the oven and to heat living spaces
for some periods or to support an insufficient centralized heating system. They are ideal for holiday apartments and
weekend houses or as an auxiliary heating system during the whole year. As fuel, wood logs is used. The continuous
fire cooker is made of galvanized and enamelled steel sheets and enamelled cast iron (doors, front side, plate ).
The hearth is totally sheathed with single cast iron sheets. Inside there is a thick, flat and extractable grate.
Below the oven door there is an extractable wood drawer, with the related closing door.
The heating of the environment is made by irradiation: through
the panoramic glass and the external hot surfaces of the stove,
the heat is radiated into the environment.
Smokes control (pull push lever)
Picture 1
A
(Conversion of the cooker function to the cooker, bake oven and
heating function).
The smokes control can be found on the top right plate of the
cooker, between the lid and the exhaust pipe. This control has
two settings:
HOB COOKING : when the bar is pushed to the back of the
cooker, the combustion gases flow around the oven and directly
into the flue and up to the chimney.
OVEN COOKING: when the control bar is pulled out, the
combustion gases flow around the oven, heating it.
3. RULES FOR INSTALLATION
The stove, assembled and ready for the installation, must be connected with a junction to the existing flue of the
house. The junction must be possibly short, straight, horizontal or positioned a little uphill. The connections must be
tight.
It is obligatory to respect the National and European rules, local regulations concerning building matter and
also fireproofs rules. Please apply to your chimney sweeper for all information.
You should verify the sufficient air entrance for the combustion in the installation place, with particular attention to
windows and doors with tight closing (seal ropes).
It is not allowed the connection of various appliances to the same chimney. The diameter of the opening for the
connection must correspond at least to the diameter of the smokes pipe. The opening should be equipped with a wall
connection for the reception of the exhaust pipe and a rose window.
The small hole for the smoke connection pipe not in use must be covered with the related cap.
Before installation, verify if your floor can support the weight of the cooker (for ex. distributing weight plate).
DAL ZOTTO is not responsible in case of modification of the product and for the use of not original spare
parts.
THE HEARTHS MUST NOT BE MODIFIED.
4. FIRE SAFETY
In the installation of the cooker the following safety measures are to be followed:
a)
In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing
components flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with
flammable structure (see Picture 2 -
A
).
All the minimum safety distances are shown on the product data
plate and lower values must not be used.
b)
In front of the hearth, in its radiation area there must not be any flammable object or construction material
sensitive to the heat at least within
100 cm’s
; This distance can be reduced to 40 cm’s if you will install in front of
the element to protect a retro ventilated and heat resistant protection.
c)
If the product is installed on a non totally refractory floor, one must foresee a fireproof background.
The floors
made of inflammable material
, such as moquette, parquet or cork etc.,
must be replaced
by a layer of no-
inflammable material, for instance ceramic, stone, glass or steel etc.
(size according to regional filing). The
platform must stick out
50 cm’s
in front and
40 cm’s
sideways (Picture 2
B
)
Picture 1
A