DVX-1200/2200/2210 Series Panel Installation & Service Quick Guide
Page 9 of 10
DD5166395
Rev 05
20 October 2023
201 Daktronics Drive
Brookings, SD 57006-5128
www.daktronics.com/support
800.325.8766
Prolink Solution
Install PLR
Prolink devices will be provided when choosing DVX-2210 Series.
The power box hook lock is different from the quick latch on DVX-
Devices and tools Needed.
•
PLR
•
PLR Support
•
Fasteners (M4x12 Countersunk Phillip head screw + M4 nut)
•
Self-drilling screw (M4x10)
•
Optical Fiber cable (Customer provided). The length and type are
according to the project’s configuration.
•
Power cable for PLR (Daktronics provided)
•
Signal cable (Daktronics provided). Female or Male end type to be
selected on site, refer to site-specific riser drawings requirements.
Figure 82:
Devices and Tools
PLR
PLR Support
Screws and Nut
Optical Fiber cable
Power cable for PLR
Signal cable
Follow these steps to install a PLR.
1.
Remove the backsheet. Refer to
.
2.
Find the pre-drilled holes on the bottom of the horizontal stiffener
underneath the power box. There are several holes on the stiffeners to
be chosen as the PLR mounting location. Refer to
Figure 83:
Pre-Drilled Holes
3.
Install the pre-assembly devices of the PLR on the stiffener using the M3
self-drilling screws. Refer to
Figure 84:
Install PLR
Reverse these steps to remove the PLR.
Power Cable Installation
1.
Locate the closed power box. Refer to
Figure 85:
Closed Power Box
2.
Plug in the PLR power cable connector, and make sure the gland nut is
Figure 86:
Plug In the PLR Power Cable Connector
3.
Plug in the PLR power cable end to the PLR board, and make sure the
connector is locked with the hook. Refer to
Figure 87:
Plug in the PLR Power Cable End
4.
Connect the incoming cable to the fiber cable connector of the PLR
board, and make sure the connector is locked with the hook. Refer to
Figure 88:
Fiber cable Installation