Electrical Installation

Power Connection 

Most standard panels come with power quick connects with  

pre-terminated connectors at each end. 
The gender is different for the power input and output ends. Power 

interconnect cables are shipped with the displays. 

In a 230 V system, up to four cabinets can be connected in parallel for a 

 

20 A breaker. A horizontal connection is typically preferred. Refer to

 

Figure 23

. Refer to the contract-specific Riser Diagram for more details.

Quick connectors are pre-assembled within the cabinets. Connect them 

across adjacent cabinets on-site. Connect the main power incoming 

cable only from the left side (when viewing from the front). Listen for a click 

to make sure the connectors are fully engaged. Refer to 

Figure 24

Signal Connection 

A DVI cable connects a computer located in the control room to a 

sending box. Some sending boxes may have additional signal input 

options, such as HDMI and SDI. The sending box passes the signal via a 

 

Cat 5e/Cat 6 cable into the receiver card inside the first panel. Each panel 

has a receiver card, and Cat 5e/Cat 6 cables daisy-chain the receiver 

cards together. If desired, the last panel can connect back to the sending 

box for redundant data to the receiver cards.

Figure 23: 

Four Cabinets Power Connection

Figure 24: 

Connect Power and Signal Quick Connectors

Power  

Quick Connector

Signal

 

Quick Connector

1. 

Connect the sending box to the computer with a DVI cable. Refer to 

Figure 25 

and 

Figure 26

.

Figure 25: 

Sending Box (Front)

Figure 26: 

Sending Box (Rear)

Connect a Cat 5e/Cat 6 cable from the sending box RJ45 output jack 

to the RJ45 quick-connect jack in the first panel. Refer to the contract-

specific Riser Diagram.

Note: 

The maximum cable distance from the sending box to the first 

receiver card is 328.08' [100 m]. For installations exceeding this 

distance, use a fiber converter to convert the Cat 5e/Cat 6 

cable to a fiber cable, which offers an additional 984.25' [300 

m] with multi-mode fiber or up to 9.32 mi [15 km] with single-

mode fiber. Two fiber converters can be used to convert the 

cable to a fiber cable and then back to a Cat 5e/Cat 6 cable. 

The cable can connect to the first panel. Use additional cables 

to connect to the next panel. Refer to 

Figure 27

 and 

Figure 28

.

Figure 27: 

Fiber Cable

2. 

Route the Cat 5e/Cat 6 cable from the signal output jack to the signal 

input jack on the next panel. Refer to 

Figure 29

 and the Riser Diagram.

Figure 29: 

Route Cables

Note: 

Routing may vary based on converter type.

Figure 28: 

Fiber Converter

3. 

Connect the last panel back to the sending box for redundant signal 

connection if desired. Refer to 

Figure 30 

for an example of 3x4 panels 

connected.

Figure 30: 

3x4 Signal Connection

Primary

Redundant

 

(optional)

Sending Box

Configuration

Refer to 

NovaStar's Website (https://www.novastar.tech/downloads/)

 and 

download the latest manual for details on how to configure the system and 

run the display.

Note: 

Refer to 

Knowledge Base

 articles on Daktronics.com

 for more 

information about using NovaStar software.

• 

"

DVX-2200: How do I configure a display via NovaStar sending box?

(

https://www.daktronics.com/en-us/support/kb/000026802

)

• 

"

NovaStar: How do I set up NovaLCT V5.4.4.3 CTM 2.0.07404 smart 

module monitoring for receiver card temperature dimming and 

light sensor dimming?

" (

https://www.daktronics.com/en-us/support/

kb/000026411

)

End Cable Solution

Daktronics provides an end connector 

(Male/Female) for the end cable 

(Power/Signal cable) connection. 

Refer to 

Figure 31.

The field engineer can choose other 

solutions if not using an end cable 

connector. The goal is to make sure 

the end cables are waterproof.

Figure 31: 

End Cable Connector

Summary of Contents for DVX-1200 Series

Page 1: ...d to the top panel of the frame Refer to Figure 4 If the value at the bottom of the structure exceeds 1 mm for each 1 m of the frame s height adjust the structure or plan ahead for panel adjustments w...

Page 2: ...ve the C clamp after installing at least two bolts through the clip angles into the structure two bolts on each side Refer to Figure 13 6 Verify the alignment of the first row Repeat Step 5 if needed...

Page 3: ...jack in the first panel Refer to the contract specific Riser Diagram Note The maximum cable distance from the sending box to the first receiver card is 328 08 100 m For installations exceeding this d...

Page 4: ...Push lock up to open Refer to Figure 35 5 Remove the connector from the rear of the module Refer to Figure 36 Figure 35 Remove Both Connector Locks 6 Before reconnecting the modules check the module m...

Page 5: ...1 Disconnect power to the display 2 Remove the module s Refer to Front Access Module Removal p 4 To access the power box from the front the top row of modules Top Left Top Center and Top Right in Figu...

Page 6: ...ing these steps 1 Disconnect power to the display 2 Remove the backsheet Refer to Figure 38 Figure 39 Figure 40 and Figure 41 3 Find the hinge stopper on the bottom of the power box and loosen the scr...

Page 7: ...screwdriver to remove the screws securing the hub board to the power box Refer to Figure 70 Figure 70 Remove Screws from Hub Board 8 Pull the hub board gently outward to remove it from the power box...

Page 8: ...d push all the way to the bottom Refer to Figure 78 The cable can be pulled out for a distance when necessary by loosening the cable gland nut Figure 78 Apply Cable Gland Removal Tool 4 Remove the con...

Page 9: ...Follow these steps to install a PLR 1 Remove the backsheet Refer to Figure 38 Figure 39 Figure 40 and Figure 41 2 Find the pre drilled holes on the bottom of the horizontal stiffener underneath the po...

Page 10: ...325 8766 5 Connect the signal cable end on the panel with the signal cable connector on the PLR board A female connector or male connector can be chosen according to site requirements Refer to the Ri...

Reviews: