DVX-1200/2200/2210 Series Panel Installation & Service Quick Guide
Page 4 of 10
DD5166395
Rev 05
20 October 2023
201 Daktronics Drive
Brookings, SD 57006-5128
www.daktronics.com/support
800.325.8766
Service
Note:
Avoid exposing the contents of the power/signal box to moisture,
as the components are not sealed for water exposure.
Module
Front-Access Module Removal
To remove a module from a front-access display, follow these steps:
1.
Disconnect power to the display.
2.
Insert the module removal tool into the keyhole on the front of the
display and turn counterclockwise. Refer to
.
Figure 32:
Front Keyhole Position
Figure 33:
Use Module Removal Tool
3.
Pull the module away from the panel. Refer to
Figure 34:
Pull the Module Away
4.
Unlock the connector from the rear of the module after the module is
removed. Push lock up to open. Refer to
.
5.
Remove the connector from the rear of the module. Refer to
.
Figure 35:
Remove Both Connector
Locks
6.
Before reconnecting the modules, check the module map in the
power-signal box to ensure proper connections. Refer to
.
Figure 37:
Module Map
Reverse these steps to install a module in a front-access display.
Rear-Access Module Removal
Note:
To access modules in the extremities of a given section, adjacent
inner modules (Middle Left, Middle Center, or Middle Right in
) may need to be removed.
To remove a module from a rear-access display, follow these steps:
1.
Disconnect power to the display.
Figure 36:
Remove Connector
2.
Remove the screws from the backsheet and lift the backsheet up and
away from the display. Refer to
,
, and
Figure 38:
Backsheet Screw
Locations
Figure 40:
Lift Backsheet Up
Figure 41:
Pull Backsheet Out
3.
Disconnect the fan cables. Refer to
Figure 42:
Disconnect Fan Cable
Figure 39:
Remove Screws from
Backsheet