Installing and Configuring a DataProbe iBoot G2 for
Street Furniture
DD2594516 Rev 1
31 July 2013
PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128
tel: 800-325-8766 fax: 605-697-4700
www.daktronics.com
Connect:
Function
iBoot-G2+
iBoot-Exp
Power
V+ Power Out
V+ Power In
Feedback
I Input
O Output
Ground
G Ground
G Ground
Command
O Output
I Input
Expansion units (iBoot-Exp) are shipped with a cable for easy connection to the iBoot-G2+. Maximum
cable length is 1000 ft. (305 m) using 22 AWG wire.
Connecting to General Purpose I/O
Function
iBoot-G2+
Description
Power
V+ Power Out
This is +12 VDC power out from the iBoot-G2+ Maximum current
100 mA
Feedback
I Input
Input for status signals. Dry Contact input or Open Collector.
Ground
G Ground
Signal Ground for Input and Output
Command
O Output
2N3904 NPN Transistor. 100 mA Maximum
Figure 4: G2+ to iBoot-EXP Connections
Summary of Contents for DSF-600 Series
Page 10: ...6 Cabinet Installation...
Page 28: ...24 Maintenance Troubleshooting...
Page 32: ......
Page 34: ......
Page 36: ......
Page 41: ......
Page 61: ......