Installing and Configuring a DataProbe iBoot G2 for
Street Furniture
DD2594516 Rev 1
31 July 2013
PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128
tel: 800-325-8766 fax: 605-697-4700
www.daktronics.com
Web Setup
iBoot-G2+ setup section consists of several pages. Access any page via the buttons on the left of the page.
Each time a setting is changed, click on the Save button for that page to save the changes before moving
to the next page.
Device Settings
Location ID
Set a 20 Character name to be displayed on the top
of the Home page. This assists in identifying which
iBoot-G2+ is being accessed.
Cycle Time
Daktronics default cycle time is 300 seconds but
can be adjusted from 0 to 999 seconds power
cycle time. This is the length of time the power
will be off during a reboot, or on during a power
burst.
Auto Logout
This setting sets the automatic logout for
inactivity on both the web and the Telnet users.
It can be set from 0 to 99 minutes. 0 disables the
Auto Logout feature.
Note:
As the iBoot-G2+ allows only one
Web user logged in at any time, use caution
when disabling the timeout feature, as
it is possible to lock out other users by
forgetting to logout. Closing the browser
will not log the user out and will lock out web access. If you do become locked out, access the
iBoot-G2+ via Telnet and reboot the unit, or
press the reset button.
Expansion Settings
Mode
Set iBoot-Exp. iBoot-Exp displays Exp1 and Exp2
as power On/Off modules.
•
iBoot-Exp Mode: Select Link to Main to
have the status of the Expansion unit be
identical to the Main outlet of iBoot-G2+.
This is convenient if switching both
power supplies of dual redundant
powered devices.
Figure 14: Location ID
Figure 15: Expansion Settings
Figure 16: Independent I/O
Figure 17: IP Mode Settings