Configuring the DM-100 Gen III  

for Sapphire Interface Quick Guide

DD2294807
Rev 04
14 September 2022

201 Daktronics Drive

Brookings, SD 57006-5128

www.daktronics.com/support

800.325.8766

Page 3 of 8

COM Diagnostics

1. 

Press the 

MENU

 key followed by 

ENTER 

to select the 

Diagnostics Menu

2. 

Press the 

Down Arrow

 key to reach 

COM Diagnostics

, and then press 

ENTER

LCD Screen

Action/Information Shown

DIAGNOSTICS
POS PORT MONITOR

DIAGNOSTICS
COM PORT TESTS

DIAGNOSTICS
POS STATUS

There are three menu choices described below:

• 

PoS Port Monitor

• 

COM Port Tests

• 

PoS Status

Press the 

Up

 and 

Down Arrow

 keys to select the appropriate menu choice. 

DIAGNOSTICS
POS PORT MONITOR

USE POS DEFALTS?
1-YES   2-NO

INCOMING DATA...

Press 

ENTER

 to begin the 

PoS Port Monitor

.

Press 

1

 to use the PoS default settings, or press 

2

 to enter the settings. 

Note: 

If 2 is pressed, see below for settings to select.

Press 

ENTER

 to exit. 

SELECT BAUD RATE
9600 }{

SELECT STOP BITS
1 {

Consult the PoS system manual for specific Baud Rate and Stop Bits as needed.

Press the 

Up

 and 

Down Arrow

 keys to select the appropriate Baud Rate, and 

then press 

ENTER

. Default Baud Rate = 9600

Press the 

Up

 and 

Down Arrow

 keys to select the appropriate Stop Bits, and then 

press 

ENTER

. Default Stop Bits = 1

DIAGNOSTICS
COM PORT TESTS

SELECT TEST }

RS232 COM0

SELECT TEST {}
RS232 COM0]COM1

SELECT TEST {}
RS232 COM1

SELECT TEST {
CURRENT LOOP

Press 

ENTER

 to test the operation of the DM-100 COM ports and/or cables. 

These tests are useful for determining if the ports themselves are operational 

and if cables are good.

Press the 

Up

 and 

Down Arrow

 keys to select the appropriate test, and then 

press 

ENTER

• 

RS232 COM0 – Checks for a “loopback” jumper on pins 2 & 3 of the top-

left connector (FAIL if a loopback is not detected).

• 

RS232 COM0->COM1 – Checks for transmit and receive connections 

between the top-left and top-right connectors (FAIL if the ports are not 

connected together).

• 

RS232 COM1 – Checks for a “loopback” jumper on pins 2 & 3 of the top-

right connector (FAIL if a loopback is not detected). 

• 

CURRENT LOOP – Checks for “loopback” jumpers on the left connector 

between pins 6 & 8 and 5 & 9 (FAIL if jumpers not detected).

Press 

ENTER

 to exit. 

DIAGNOSTICS
POS STATUS

This menu is only used for internal Daktronics testing purposes. 

COM DIAGNOSTICS
ENT TO SELECT

Summary of Contents for DM-100 Gen III

Page 1: ...eys until the gas price option is shown Press the ENTER key to accept Menu Navigation 1 Press the MENU key 2 Press the Up and Down Arrow keys to select between available menu options 3 Press ENTER to...

Page 2: ...ng the network configuration the RTX message may appear in the upper right corner of the LCD to indicate the DM 100 is attempting to re connect to all detected networks Test Patterns 1 Press the MENU...

Page 3: ...Down Arrow keys to select the appropriate Baud Rate and then press ENTER Default Baud Rate 9600 Press the Up and Down Arrow keys to select the appropriate Stop Bits and then press ENTER Default Stop...

Page 4: ...TER to open the Price Options menu item LCD Screen Action Information Shown ACTIVE PRICES 123 ACTIVE PRICES 23 ACTIVE PRICES 1 3 ACTIVE PRICES 3 ACTIVE PRICES 12 ACTIVE PRICES 2 ACTIVE PRICES 1 SET HO...

Page 5: ...e Address and Line assignments Press CLEAR SET FUNCTION to map lines in the next network Continue pressing CLEAR SET FUNCTION to exit to the main screen CONFIGURATION STYLE SELECT STYLE NO TAILS 9 10...

Page 6: ...line PoS Price Offset 1 Press the MENU key 2 Press the Down Arrow key to reach Display Menu and then press ENTER 3 Press the Down Arrow key to reach PoS Price Offset and then press ENTER LCD Screen Ac...

Page 7: ...each display to detect the level of ambient light at the display location and dim the LED brightness accordingly Manual Dimming retains the same LED brightness level regardless of the level of light...

Page 8: ...ress ENTER To leave the sign blank press CLEAR Set Petroleum Prices Each line automatically updates when the price is changed in the PoS system The following error appears when attempting to edit pric...

Reviews: