[8]
MAN #650695
Enabling Air Fuel Ratio:
The BIM-01-2-J1939 has an option to monitor Air Fuel Ratio.
•
Hold the switch on the BIM-01-2-J1939 case while turning the key on. The BIM display will show the current
revision code while this is held.
•
Release the switch.
•
Tap the switch until the display shows
(Air Fuel). Press and hold to enter this menu.
•
When you see
on the display release the switch.
•
The display will show the current boost state,
(disable) or
(enable).
•
Tap the switch to change the state.
•
To save setting press and hold the switch until you see
on the display, then release the switch.
•
The display will show
. Press and hold the switch to exit setup or tap to choose another menu option.
Enabling Fuel Pressure:
The BIM-01-2-J1939 has an option to monitor Fuel Pressure.
•
Hold the switch on the BIM-01-2-J1939 case while turning the key on. The BIM display will show the current
revision code while this is held.
•
Release the switch.
•
Tap the switch until the display shows
(Fuel Pressure). Press and hold to enter this menu.
•
When you see
on the display release the switch.
•
The display will show the current boost state,
(disable) or
(enable).
•
Tap the switch to change the state.
•
To save setting press and hold the switch until you see
on the display, then release the switch.
•
The display will show
. Press and hold the switch to exit setup or tap to choose another menu option.
Enabling Oil Temp:
The BIM-01-2-J1939 has an option to monitor Oil Temp.
•
Hold the switch on the BIM-01-2-J1939 case while turning the key on. The BIM display will show the current
revision code while this is held.
•
Release the switch.
•
Tap the switch until the display shows
(Oil Temp). Press and hold to enter this menu.
•
When you see
on the display release the switch.
•
The display will show the current boost state,
(disable) or
(enable).
•
Tap the switch to change the state.
•
To save setting press and hold the switch until you see
on the display, then release the switch.
•
The display will show
. Press and hold the switch to exit setup or tap to choose another menu option.
To view the current BIM ID numbers:
•
Hold the switch on the BIM-01-2-J1939 case while turning the key on. The BIM display will show the current
revision code while this is held.
•
Press and release the switch until the display shows
(LIN channels).
•
Press and hold to enter this menu. When you see
on the display, release the switch.
•
The display will show
followed by the current ID of the boost option (for example:
). Pressing the switch will
cycle through the options, displaying the currently assigned IDs to the boost option. If the option is disabled, the
display will show
.
•
To exit this menu, press and release the switch until
is displayed. Then press and hold the switch until
is
displayed.
•
The display will display the next available menu. Press and hold the switch to enter that menu or press and
release the switch to select another menu.
•
To exit, press and release the switch until the display shows
then press and hold the switch until you see
on the display.
To automatically set bus ID numbers:
•
Hold the switch on the BIM-01-2-J1939 case while turning the key on. The BIM display will show the current
revision code while this is held.
•
Press and release the switch until the display shows
(auto channel).
•
Press and hold to enter this menu. When you see
on the display, release the switch.
•
The display will display
,
, then
as the BIM automatically determines the best ID to assign for the boost
option (if enabled).
•
The display will show
. Press and hold the switch to exit setup or press and release to choose another menu
option.
Summary of Contents for BIM-01-2-J1939