MAN 650067:G
23
Oil pressure warning setup (
WARN
)
This menu will allow you to select the low pressure warning point. When the display
value is lower than this point, the OIL display will flash. The value is adjustable from 5 – 36 psi.
•
When “
WARN
” is displayed, press and hold SW1 until you get “ - ”.
•
Release SW1 and the current warning point will be displayed.
•
Press and release SW1 to increase the value from “
LO 05
” – “
LO 36
”.
•
When the desired value is displayed press and hold SW1 until “
-
” “
DONE
” is displayed.
•
Release the switch to go onto the next menu item.
Oil pressure sensor test (
TEST
)
This menu will allow you to check the voltage the control box is reading from the pressure
sensor. This can be used for a diagnostic tool if you are having trouble or feel that the reading
is incorrect. For the Dakota Digital SEN-03-8, 0-100 psi sensor, the voltage increases with
pressure. At 0 psi, the voltage should be close to 0.5V at 100 psi the voltage should be close to
4.5V.
•
When “
TEST
” is displayed, press and hold SW1 until you get “
-
”
•
Release SW1 and the current voltage from the pressure sensor will be displayed on the
speedometer and “
V OIL
” is displayed on the odometer readout.
•
Press and release SW1 to scroll through the next sensor input if you wish “
R FUEL
”
“
R TEMP
” “
V OIL
”
•
Once complete, hold SW1 until “
-
” “
DONE
” is displayed.
•
Release the switch to go onto the next sub-menu item.
Exit oil pressure setup (
DONE
)
This will allow you to exit the oil pressure setup and go on to the next setup menu.
•
When “
Se
Se
Se
Set
DONE
” is displayed, press and hold SW1 until you get “
-
” “
DONE
”
•
Release the switch to go onto the next menu.
FUEL SETUP
The control box can read seven common fuel level sender resistance values. If your
sender is not shown in the table below, the system can be programmed to read a custom
sender. If “
BUS
” is selected for the sender type, the fuel level should be coming into the AUX I/O
port through the use of a BIM module. The table below shows the seven pre-programmed
senders and their respective empty and full resistance values.
Sender type
Menu
Empty R
Full R
GM 0-30 ohm (mid 60’s-earlier)
GM 30
0 ohms
30 ohms
GM 0-90 ohm (mid 60’s-late 90’s)
GM 90
0 ohms
90 ohms
GM 40-250 ohm (late 90’s-later)
GM 250
40 ohms
249 ohms
FORD 73-10 ohm (earlier -late 80’s)
F 10
73 ohms
10 ohms
FORD 20-150 ohm (late 80’s-later)
F 150
20 ohms
150 ohms
VDO 10-180 ohm
V 180
10 ohms
180 ohms
SW/SUN 240-33
SW 33
240 ohms
33 ohms
User programmed
CUSTOM User settable User settable
•
Press and hold SW1 while turning the key on.
•
Release the switch and then press and release SW1 to get to the “
FUEL
” setup menu.
•
Press and hold the switch until “
FUEL
” is displayed to enter the fuel setup menus, then
release SW1.
•
Now you can press and release the switch to scroll through the fuel sub-menus, “
SENDER
”
“
CUSTOM
” “
TEST
” “
DONE
”.
•
When you get to the desired sub-menu, press and hold the switch to select it.