MAN 650067:G
20
Display update setup (
UPDATE
)
The display update rate can be adjusted so the reading on the tachometer doesn’t
change so quickly. This is a personal preference and is used to “slow” the reading by
averaging. The value can be changed from slow, mid, or fast.
•
When “
UPDATE
” is displayed, press and hold SW1 until you get “
-
”.
•
Release SW1 and the current update rate will be displayed.
•
Press and release SW1 to increase the value from “
SLOW
” “
MID
”
“
FAST
”.
•
When the desired setting is displayed, press and hold SW1 until “
-
” “
DONE
” is displayed.
•
Release the switch to go onto the next sub-menu item.
RPM warning setup (
WARN
)
This is used for the turn on point for the WARN output on the control box. When the
RPM reading is above this setting, the output will activate, providing a ground signal. It can be
used to turn on a shift light or other RPM based devices. The value is adjustable from 2200
RPM – 14800 RPM in 100 RPM increments.
•
When “
WARN
” is displayed, press and hold SW1 until you get “
-
”.
•
Release SW1 and the current warning point will be displayed.
•
Press and release SW1 to increase the value from “
W 2200
” – “
W14800
”.
•
When the desired setting is displayed press and hold SW1 until “
-
” “
DONE
” is displayed.
•
Release the switch to go onto the next sub-menu item.
Tach signal setup (
SIGNAL
)
This menu will allow you to select from two different tach-input types. A low voltage, “
5
LO
”, tach signal or a high voltage tach signal, “
12 HI
”. A low voltage signal is usually one
picked up from the ECM. Low voltage may also be considered a 0-5V square wave. If you are
getting the tach signal from the ignition coil or points, set this for the high voltage signal “
12 HI
”.
To pick up a tach signal from a traditional coil, wire the tach input to the negative side of the coil.
•
When “
SIGNAL
” is displayed press and hold SW1 until you get “
-
”.
•
Release SW1 and the current value will be displayed.
•
Press and release SW1 to toggle from “
12 HI
” to “
5 LO
”.
•
When the desired setting is displayed, press and hold SW1 until “
-
” “
DONE
” is displayed.
•
Release the switch to go onto the next sub-menu item.
Exit tach setup (
DONE
)
This will allow you to exit the tach setup and go on to the next setup menu.
•
When “
Se
Se
Se
Set
DONE
” is displayed, press and hold SW1 until you get “
-
” “
DONE
”.
•
Release the switch to go onto the next menu .
VOLT SETUP
The Volt setup allows you set a warning point that will cause the Volt display to flash
whenever the voltage drops below the warning value. The low voltage point can be set from 10
-13.1 volts.
•
Press and hold SW1 while turning the key on.
•
Release the switch and then press and release SW1 to get to the “
VOLT
” setup menu.
•
When “
VOLT
” is displayed press and hold SW1 until you get “
-
”, release SW1 and “
WARN
”
will be displayed.
•
When “
WARN
” is displayed, press and hold SW1 until you get “
-
”.
•
Release SW1 and the current warning point will be displayed.
•
Press and release SW1 to increase the value from “
LO 10.0
” – “
LO 13.1
”.
•
When the desired setting is displayed, press and hold SW1 until “
-
” “
DONE
” is displayed.
•
Release the switch to go onto the next sub-menu item.