background image

LineFit Light-LED (LFL-LED)

LED Lighting System

Installation Guide

SIGN182 | GE2028-6426

RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN 

ACCORDANCE WITH KIT INSTRUCTIONS.

KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY 

THE INSTRUCTIONS ARE PRESENT.

TROUSSE DE CONVERSION À DEL POUR LA 

MODERNISATION DES ENSEIGNES

À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.

Electrical Requirements

•  Limited to use in dry and damp locations.

•  The grounding and bonding of the LED Driver shall be done in 

accordance with National Electric Code (NEC) Article 600.

•  Follow all National Electric Codes (NEC) and local codes.

•  These products are only suitable for connection to a circuit 

from a Class 2 power source.

•  These products have not been evaluated for use when 

connected to a power source that does not comply with Class 2 

voltage and energy limited supplies.

Save These Instructions

Use only in the manner intended by the manufacturer. If you 

have any questions, contact the manufacturer.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005  du Canada.

 

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK

 ∙

Turn power off before inspection, installation or removal.

 ∙

Properly ground power supply enclosure.

RISK OF FIRE

 ∙

Use only UL approved wire for input/output connections. 

Minimum size 18 AWG (0.82mm

2

)

 ∙

Follow all NEC and local codes.

 ∙

Not to be submerged or used in a marine environment.

RISK OF FIRE OR ELECTRIC SHOCK

 ∙

LED Retrofit Kit installation requires knowledge of sign 

electrical systems. If not qualified, do not attempt installation. 

Contact a qualified electrician.

 ∙

Install this kit only in host signs that have been identified in the 

installation instructions and where the input rating of the retrofit 

kit does not exceed the input rating of the sign.

 ∙

Installation of this LED retrofit kit may involve drilling or 

punching of holes into the structure of the sign. Check for 

enclosed wiring and components to avoid damage to wiring 

and electrical parts.

 ∙

Do not make or alter any open holes in an enclosure of wiring 

or electrical components during kit installation.

RISQUES DE DÉCHARGES ÉLECTRIQUES

 ∙

Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.

 ∙

Assurez-vous de correctement mettre à terre l’alimentation électrique.

RISQUES D’INCENDIE

 ∙

N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. 

Taille minimum 18 AWG (0.82mm

2

)

 ∙

Respectez tous les codes NEC et codes locaux.

 ∙

Ne pas submerger ou installer dans un environnement marin.

RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE 

 ∙

L’installation de l’équipement de remplacement DEL exige Ia connaissance 

des systèmes électriques pour enseignes. Si non qualifié, ne tentez pas 

d’installation. Veuillez contacter un électricien qualifié.

 ∙

Risque d’incendie ou de choc Électrique. Installez cet ensemble seulement dans des 

enseignes hôtes qui ont été identifiés dans les instructions d’installation et dont la 

capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de l’enseigne.

 ∙

L’installation de cet équipement de remplacement DEL peut impliquer le 

perçage ou le poinçonnage de trous dans la structure du panneau Vérifiez le 

câblage et les composants inclus pour éviter d’endommager le câblage et les 

composants électriques.

 ∙

Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage ou de 

composants électriques pendant l’installation de cet équipement de remplacement DEL.

Prepare Electrical Wiring

24

Volt

(GEF18xxxHOLED-1, GEF24xxxHOLED-1, GEF30xxxHOLED-1, GEF36xxxHOLED-1, 

GEF42xxxHOLED-1, GEF48xxxHOLED-1, GEF60xxxHOLED-1, GEF64xxxHOLED-1, 

GEF72xxxHOLED-1, GEF84xxxHOLED-1, GEF96xxxHOLED-1)*

* key for xxx: D = Daylight (6500K), SGN = Sign White (5400K), CW = Cool White (4100K)

BEFORE YOU BEGIN

Read these instructions completely and carefully.