background image

2

While following the instructions in this installation manual,

install drain piping to ensure proper drainage and insulate

piping to prevent condensation.

Improper drain piping may result in indoor water leakage and

property damage.

Install the indoor and outdoor units, power cord and connect-

ing wires at least 1 meter away from televisions or radios to

prevent picture interference and noise.

(Depending on the incoming signal strength, a distance of 1

meter may not be sufficient to eliminate noise.)

Remote controller (wireless kit) transmitting distance can be

shorter than expected in rooms with electronic fluorescent

lamps (inverter or rapid start types).

Install the indoor unit as far as possible from fluorescent

lamps.

!

CAUTION

Do not install the air conditioner in the following locations:

1.

2.

Where there is a high concentration of mineral oil spray or

vapour (e.g. a kitchen).

Plastic parts will deteriorate, parts may fall off and water

leakage could result.

Where corrosive gas, such as sulphurous acid gas, is pro-

duced.

Corroding of copper pipes or soldered parts may result in

refrigerant leakage.

3.

4.

Near machinery emitting electromagnetic radiation.

Electromagnetic radiation may disturb the operation of the

control system and result in a malfunction of the unit.

Where flammable gas may leak, where there is carbon

fibre or ignitable dust suspensions in the air, or where

volatile flammables such as paint thinner or gasoline are

handled.

Operating the unit in such conditions may result in fire.

The air conditioner is not intended for use in a potentially

explosive atmosphere.

Do not touch the heat exchanger fins.

Improper handling may result in injury.

Be very careful about product transportation.

Some products use PP bands for packaging. Do not use any

PP bands for a means of transportation. It is dangerous.

Safely dispose of the packing materials.

Packing materials, such as nails and other metal or wooden

parts, may cause stabs or other injuries.

Tear apart and throw away plastic packaging bags so that

children will not play with them. If children play with a plastic

bag which was not torn apart, they face the risk of suffocation.

Do not turn off the power immediately after stopping operation.

Always wait at least 5 minutes before turning off the power.

Otherwise, water leakage and trouble may occur.

In a domestic environment this product may cause radio

interference in which case the user may be required to take

adequate measures.

When moving the unit while removing it from the carton

box, be sure to lift it by holding on to the four lifting lugs

without exerting any pressure on other parts, especially,

the refrigerant piping, drain piping, flanges and other

resin parts.

Be sure to check the type of R410A refrigerant to be used

before installing the unit. (Using an incorrect refrigerant will

prevent normal operation of the unit.)

The accessories needed for installation must be retained in

your custody until the installation work is completed. Do not

discard them!

Decide upon a line of transport. Decide transportation medium.

Leave the unit inside its packaging while moving, until reach-

ing the installation site. Where unpacking is unavoidable, use

a sling of soft material or protective plates together with a

rope when lifting, to avoid damage or scratches to the unit.

For the installation of outdoor unit, refer to the installation

manual attached to the outdoor unit.

Do not install or operate the unit in rooms mentioned below.

Laden with mineral oil, or filled with oil vapor or spray

like in kitchens. (Plastic parts may deteriorate which

could eventually cause the unit to fall out of place, or

could lead to leaks.)

Follow national standards for installation work.

2. BEFORE INSTALLATION

Where corrosive gas like sulfurous gas exists. (Cop-

per tubing and brazed spots may corrode which could

eventually lead to refrigerant leaks.)

Where exposed to combustible gases and where

vol-atile flammable gas like thinner or gasoline is

used.(Gas in the vicinity of the unit could ignite.)

Where machines can generate electromagnetic

waves. (Control system may malfunction.)

Where the air contains high levels of salt such as that

near the ocean and where voltage fluctuates greatly

such as that in factories.

Also in vehicles or vessels.


Be sure to read this manual before installing the indoor unit.

Entrust installation to the place of purchase or a qualified ser-

viceman. Improper installation could lead to leaks and, in

worse cases, electric shock or fire.

This unit, both indoor and outdoor, is suitable for installation

in a commercial and light industrial environment.

If installed as a household appliance it could cause electro-

magnetic interference.

2-

1

  PRECAUTIONS

Check that the following accessories are provided and that each 
accessory is correct in amount.
Refer to the Fig. 1 of this sheet.
[PRECAUTION]
The accessories are required for the installation of the air con-
ditioner. Be sure to keep them until the installation work is 
completed

Use only parts provided with the unit or parts satisfying

required specifications. Unspecified parts could cause the

unit to fall out of place, or could lead to leaks and, in worse

cases, electric shock or fire.

Be sure to mount an air filter (part to be procured in the field)

in the suction air passage in order to prevent water leaking,

etc.

2-

2

  ACCESSORIES

Fig. 1

Installation & 

Operation 

 

Manual

(1)-(11)

Summary of Contents for VRV FXMQ100ARV16

Page 1: ... shocks or fire Install the air conditioner on a foundation strong enough to withstand the weight of the unit A foundation of insufficient strength may result in the equipment falling down and causing injury Carry out the specified installation work after taking into account strong winds typhoons or earthquakes Failure to do so during installation work may result in the unit falling and causing ac...

Page 2: ...ut exerting any pressure on other parts especially the refrigerant piping drain piping flanges and other resin parts Be sure to check the type of R410A refrigerant to be used before installing the unit Using an incorrect refrigerant will prevent normal operation of the unit The accessories needed for installation must be retained in your custody until the installation work is completed Do not disc...

Page 3: ...eliver instruction manual if any for the field supplies to the customer Hold the hanging brackets in the case of moving the indoor and outdoor units at the time of and after opening the packages Do not impose undue force on other parts such as the refrigerant piping drain piping or flanges in particular Add heat insulation material to the indoor unit if the tem perature above the ceiling is likely...

Page 4: ...icing purposes of the el compo box and drain pump prepare one of the following service spaces 1 2 Inspection hatch 1 2 450 450 for the el compo box and a minimum space of 300 mm for the lower part of the product Refer to Fig 2 2 Inspection hatch 1 450 450 for the el compo box and inspection hatch 2 for the lower part of the prod uct see axial direction view A 1 Refer to Fig 2 3 3 Inspection hatch ...

Page 5: ...the washer for the hanging bracket can be prevented if the washing fixing plate 8 is used During the installation work perform the curing of the air outlet and protect the resin drain pan of the indoor unit from the intrusion of foreign substances such as welding spatters Otherwise water leakage may occur as a result of damage such as hole damage to the resin drain pan 2 Make adjustments so that t...

Page 6: ...e free of oil The drain pan and the resin part may be deteriorated if oil is attached If no torque wrenches are available refer to Table 3 as a standard When the flare nut is tightened with the spanner the tightening torque should increase suddenly Tighten the flare nut further for the corresponding angle shown in Table 3 Table 3 Torque wrench Spanner Piping union Flare nut Fig 4 Pipe size Tighten...

Page 7: ...r of 25 mm Make sure that the piping is short enough with a down ward slope of at least 1 100 and that there is no air bank formed No drain trap is required The drain piping will be clogged with water and water leak age may result if the water is accumulated in the drain piping Conduct drain up piping work if the gradient is insufficient Attach a support bracket at 1 to 1 5 m intervals for the pre...

Page 8: ...oling operation according to 11 FIELD SETTING and 12 TEST OPERATION Make sure that the water is not spilled onto the electric parts of the drain pump and others Ceiling slab 1 1 5 m 300 mm max 700 mm max Support bracket Drain up piping field supply Adjustable 467 mm max Metal clamp 1 accessory Drain hose 2 accessory Drain hose 2 accessory Horizontal or upward slope If there is an air bank noise ma...

Page 9: ...ng and piping between the outdoor unit and an indoor unit are mismatched the system may cause a malfunction A circuit breaker capable of shutting down power supply to the entire system must be installed Refer to the installation manual attached to the outdoor unit for the size of power supply wiring connected to the outdoor unit the capacity of the circuit breaker and switch and wiring instruction...

Page 10: ... connections are done fill in any gaps in the through holes with putty or insulation procured locally to prevent small animals and insects from entering the unit from outside If any do get in they could cause short circuits in the el compo box 5 Mount the provided wire fixing bracket 10 with the wire fixing screw 11 Fix each wire with the provided clamp 7 Precaution s for Power Supply Wiring Conne...

Page 11: ...rt a screwdriver into the clearance between the grooves of the lower casing and the upper casing to remove the upper casing 2 grooves The remote controller PCB is attached to the upper casing Note There is no need to set the indoor unit address when using group control It is automatically set when the power is turned on Lower part of remote controller Upper part of remote controller Insert the scr...

Page 12: ...mpossible by remote controllers Input OFF ON turns ON unit Input OFF enables control by remote con troller Input ON OFF turns OFF unit F2 T1 T2 FORCED OFF Input A SETTING MODE NO SECOND CODE NO FIELD SET MODE FIRST CODE NO 2 Filter Sign Settings The remote controller is provided with an LCD that tells the time of air filter cleaning If the air conditioner is used in places with excessive dust chan...

Page 13: ...ndoor unit indoor control PCB transmission error C6 Lit Improper combination of fan driver PCB of indoor unit or setting failure in control PCB type Test operation of outdoor unit has not U3 Lit been finished Contents Remote Controller Display is Lit up U4 is lit up UH is lit up No display The Power on the outdoor unit is off The outdoor unit has not been wired for power supply Incorrect wiring fo...

Page 14: ...nformation regarding safety Be sure to observe all precautions without fail WARNING Failure to follow these instructions properly may result in personal injury or loss of life CAUTION Failure to observe these instructions properly may result in property damage or personal injury which may be seri ous depending on the circumstances After reading keep this manual in a convenient place so that you ca...

Page 15: ...n order to prevent electric shock or fire 10 Air filter inside filter chamber Sold separately 11 Suction filter chamber Sold separately 12 Suction duct Field supply 13 Machine nameplate The nameplate is imprinted with the machine name and specifications 14 Suction grille Field supply 15 Air Filter Only a qualified person is allowed to perform mainte nance except daily maintenance Before touching a...

Page 16: ...e controller please clean the filter When the operating time exceeds the desig nated time this mark will be displayed If using the air conditioner under very dusty environment increase the frequency of air filter cleaning When you want to change the setting time until the mark is displayed consult with your dealer The default factory setting is 2500 hours There are the following time display patte...

Reviews: