SE-04753
[Operation Manual]
32/49
DAIKIN INDUSTRIES, LTD.
Setting range
Initial setting
Operating range
Note1
Parameter
No.
Description
SUT03S15 SUT03S30
SUT03S15
SUT03S30
Display unit
P00
Start/stop signal switching
1
0: Run at signal input
1: Stop at signal input
-
0 to 35.0 (0: Disabled)
(MPa)
P01
Pressure switch setting
0
0 to 507 (0: Disabled)
[When PSI unit is
selected, 10PSI]
P02
Pressure alarm output delay time setting
0
0.00 to 9.99
(9.99 sec. max.)
(sec)
P03
Pressure switch display hold setting
0
0: Disabled
1: Holds display during pressure
switch activation
2: Display and memory during
pressure switch activation
-
P04
Pressure unit selection setting
0
0: MPa
1: PSI
-
P05
Regenerative load command ratio setting
50
30 to 100
(%)
P06
AC fan motor synchronization setting
0
0: Continuous operation
1: Synchronous operation
-
P07
Warning output level setting
0
0: No warning output
1: Warning status output
2: Alarm equivalent output
-
P08
Alarm output combination setting
1
0: Individual alarm output
1: Integrated alarm output
See Attachment.
Note 6
-
P09
Reset to factory setting
0
0: Retains current settings
1: Reset to factory settings
Note 7
-
P10
Response gain
Note 2
25
20
5 to 999
(A smaller value makes quicker
response.)
-
P11
Acceleration response gain
Note 2
200
0 to 500
-
P12
Solenoid valve response delay time
0
0.00 to 9.99
(sec)
P-Q selection 0 to 15 Pressure, flow rate, acceleration time and deceleration time settings
1.5
1.5 to 7.0
(MPa)
P.00 to P.15: Pressure setting
Note 3
22
22 to 100
( 10 PSI)
q.00 to q.15: Flow rate setting
Note 4
15.2
28.5
2.4 to 15.2
3.4 to 28.5
(L/min)
Note 5
U.00 to U.15: Acceleration time setting
0.10
0.01 to 9.99
(sec/MPa)
(sec/1000min
-1
)
P13 to P28
Note 5
d. 00 to d.15: Deceleration time setting
0.10
0.01 to 9.99
(sec/MPa)
(sec/1000min
-1
)
Note 1 For setting or adjustment on the operation panel, a value exceeding the above operating range can be specified.
However, be sure to use the unit within the specified operating range.
Note 2 If the load volume is normal, response gain adjustment is not required. If the response gain is changed to an
improper value, the unit operation becomes unstable, or surge pressure may be generated.
Note 3 Make sure that the pressure setting is lower than
“
Safety valve setting
–
0.5 MPa
”
.
Note 4 The flow rate setting can be arbitrarily specified in steps of 0.1 L/min.
Note 5 According to the acceleration time setting, increases in both pressure and speed (flow rate) are simultaneously
specified.
According to the deceleration time setting, decreases in both pressure and speed (flow rate) are simultaneously
specified.
Note 6 Specify whether to activate the contact outputs (alarm, warning and pressure switch outputs) individually, or
integrate them into one output.
Note 7 1: Enables reset to factory settings. When the power supply is turned ON again, the factory settings become
active.