SE-04753
[Operation Manual]
27/49
DAIKIN INDUSTRIES, LTD.
An example of monitor mode operation is shown below.
<Example> Monitoring current discharge rate
Operating procedure
Key
operation
3-digit LED
Remarks
Power-ON
(Startup, Run)
Actual pressure display
Shift to monitor mode
Parameter No. selection
Press the
key three
times.
Blinking
Monitor display
Discharge rate
(theoretical value)
3.6 L/min
Return to actual pressure display
mode
To monitor other parameter, return to the actual pressure display mode once, and then select a desired item.