(3) Attach sealing pad as shown in the right
figure. (Stored in outlet vent) (only for
CDXS)
(In order to take in the air inside the
ceiling, and when not taking in air from
outdoor air, it is not necessary to stick.)
• Attach the sealing pad (accessory) to
the plate metal sections which are not
covered by anti-sweat material.
• Make sure there are no gaps between
the different pieces of sealing pad.
Air inlet
(3)
Air outlet
Air outlet
Air inlet
Anti-sweat material
included with the product
Anti-sweat material
included with the product
Sealing pad (Small)
For rear intake type
Sealing pad (Large)
Sealing pad (Small)
(accessory)
(accessory)
Sealing pad
(Large)
(accessory)
(accessory)
For bottom intake type
(4) Attach the hanger (right) insulation to the right hanger. (Stored in outlet vent)
(See the below figure for the sticking base line.)
Hanger (right) insulation
(accessory)
Slit
Stic
king base line
Hanger bracket (right)
Arrow view
(5) Attach the air filter (accessory) in the manner shown in the diagram.
In case of bottom side
In case of back side
Filter
Push
Push
Main unit
Attach the filter to
the main unit while
pushing down on
the bends. *
* FDXS09/12, CDXS15/18 : 2 bends
CDXS24 : 3 bends
■
When two indoor units are installed in one room, one of the two wireless remote controllers can be easily
set for another addresses.
J4
ADDRESS
EXIST
1
CUT
2
PCB in the indoor unit
• Cut the jumper
JA on PCB.
• Cut the jumper J4.
Wireless remote controller
1
2
3
JA
ADDRESS:
CUT
EXIST 1
2
ADDRESS
JA
JB
JC
J4