Safety Precautions

 WARNING

• After connecting all wiring be sure to shape the cables so that they do not put undue stress on the electrical 

covers, panels or terminals.

Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, fire or equipment damage.

• When installing or relocating the system, be sure to keep the refrigerant circuit free from all substances other than 

the specified refrigerant (R410A), such as air.

(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise which may result in rupture, resulting 
in injury.)

• During pump-down, stop the compressor before removing the refrigerant piping.

If the compressor is still running and the shut-off valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, 
causing abnormally high pressure which could lead to equipment damage or and personal injury.

• During installation, attach the refrigerant piping securely before running the compressor.

If the refrigerant pipes are not attached and the shut-off valve is open when the compressor is run, air will be sucked in, causing abnormal 
pressure in the refrigeration cycle, which may result in equipment damage and even injury. 

• Install a leak circuit breaker, as required.

If a leak circuit breaker is not installed, electric shock may result.

• Be sure to install a ground fault circuit interrupter breaker.

Failure to install a ground fault circuit interrupter breaker may result in electrically shocks or personal injury.

 CAUTION

• Establish drain piping according to the instructions of this manual.

Inadequate piping may cause water damage.

• Note for installing the outdoor unit. (For heat pump model only.) 

In regions of the country where the outside temperature is at or below the freezing point, the drain may freeze. If so, it is recommended that an 
electric heater be installed in order to protect the drain from freezing.

• Tighten the flare nut according to the specified torque. A torque wrench should be used.

If the flare nut is tightened too much, the flare nut may crack over time and cause refrigerant leakage.

• Do not touch the heat exchanger fins.

Improper handling may result in injury.

• Be very careful about product transportation.

Some products use PP bands for packaging. Do not use any PP bands for a means of transportation. It is dangerous.

Accessories

Wireless 

remote 

controller

1 pc.

Screws for 

conduit 

mounting plate

2 pcs.

Insulation 

tube

1 pc.

Dry battery 

AAA. LR03 

(alkaline)

Mounting 
frame

Screws 
M4 × 25

Decorative 
cover

Remote 

controller 

holder

1 pc.

1 pc.

1 pc.

Receiver kit

Air filter

1 set

1 pc.

2 pcs.

2 pcs.

Clamp 

metal

1 pc.

1 pc.

Insulation 

for fitting

1 each

Sealing pad

Large and 

small

1 each

for gas pipe

for liquid pipe

One is spare

Large

Small

24 pcs.

4 pcs.

Washer for 

hanger 

bracket

8 pcs.

2 pcs.

6 pcs.

1 set

Drain hose

Sealing

material

Clamp

Washer 

fixing plate

1 set

Screws for 

duct flanges

Stored in outlet vent

1 pc.

Hanger 

(right)

insulation

[ Other ]

• Operation manual

• Installation manual

1 pc.

Conduit 

mounting 

plate

3 pcs. 

(only for 

CDXS)

2 large

1 small

01_EN_3P297301-3C.indd   2

10/26/2012   11:27:22 AM

Summary of Contents for SUPER MULTI NX CDXS18LVJU

Page 1: ...ANUAL R410A Split Series Installation manual Manuel dinstallation Manual de instalación English Français Español MODELS FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU Manuel dinstallation 00_CV_3P297301 3C indd 1 10 26 2012 11 23 56 AM ...

Page 2: ...bags so that children will not play with them Children playing with plastic bags face the danger of death by suffocation Do not install unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death Do not ground units to telephone wires or lightning rods because lightning strikes could cause a severe shock hazard resulting in severe injury or d...

Page 3: ...ault circuit interrupter breaker may result in electrically shocks or personal injury CAUTION Establish drain piping according to the instructions of this manual Inadequate piping may cause water damage Note for installing the outdoor unit For heat pump model only In regions of the country where the outside temperature is at or below the freezing point the drain may freeze If so it is recommended ...

Page 4: ...ough reinforce the ceiling before installing the unit Installation pitch is marked on the carton box for installation Refer to it to check for points requiring reinforcing Select the H dimension such that a downward slope of at least 1 100 is ensured as indicated in Drain Piping Work The installation pitch is listed on the packing material and should be checked when deciding whether to reinforce t...

Page 5: ... to reinforce the ceiling frame to prevent shaking Consult an architect or carpenter for details Install the suspension bolts Use W3 8 to M10 suspension bolts Use a hole in anchor sunken insert sunken anchor for existing ceilings and a sunken insert sunken anchor or other part to be procured in the field to reinforce the ceiling to bearing the weight of the unit Refer to Fig 19 11 16 500 17 3 4 45...

Page 6: ...cessory accessory For bottom intake type 4 Attach the hanger right insulation to the right hanger Stored in outlet vent See the below figure for the sticking base line Hanger right insulation accessory Slit Sticking base line Hanger bracket right Arrow view 5 Attach the air filter accessory in the manner shown in the diagram In case of bottom side In case of back side Filter Push Push Main unit At...

Page 7: ... with water In using a plastic tube instead of a level adjust the top surface of the unit to the surface of the water at both ends of the plastic tube and adjust the unit horizontally One thing to watch out for in particular is if it is installed so that the slope is not in the direction of the drain piping as this might cause leaking Tighten the upper nut Mounting the receiver Mount the receiver ...

Page 8: ...o prevent damage to the flare nuts and escaping gas Flare nut tightening torque Gas side Liquid side 3 8 inch 9 5mm 1 2 inch 12 7mm 5 8 inch 15 9mm 1 4 inch 6 4mm 24 1 29 4ft lbf 32 7 39 9N m 36 5 44 5ft lbf 49 5 60 3N m 45 6 55 6ft lbf 61 8 75 4N m 10 4 12 7ft lbf 14 2 17 2N m CAUTION Overtightening may damage the flare and cause leaks 3 After the work is finished make sure to check that there is...

Page 9: ...ness 13 32 inch 10mm Min 1 3 16 inch 30mm or more 1 9 16 inch 40mm or more 1 15 16 inch 50mm or more 1 3 16 inch 30mm or more Thickness 0 031 inch 0 8mm C1220T O Thickness 0 039 inch 1 0mm C1220T O Thickness 0 031 inch 0 8mm C1220T O Also when subject to high humidity heat insulation of the refrigerant piping the unit piping and branch piping must be further reinforced Reinforce the insulation whe...

Page 10: ... the indoor unit through the drain pipes and corrode the heat exchanger Do not twist or bend the drain hose so that excessive force is not applied to it This type of treatment may cause leaking After piping work is finished check drainage flows smoothly Gradually insert approximately 1L of water into the drain pan to check drainage in the manner described below Gradually pour approximately 1L of w...

Page 11: ...laths of the net or fence shape or metal plating into wooden buildings Wiring See the installation manual supplied with the outdoor unit HOW TO CONNECT WIRINGS Wire only after removing the control box cover as shown in the Fig Remote controller wiring Control box cover Wiring Diagram rear Conduit mounting plate accessory Conduit field supply Lock nut field supply Screw accessory Power supply wiring ...

Page 12: ...e control box cover Next pull the wires into the unit through the conduit and thread them through the insulation tube accessory then connect to the power wiring terminal block 4P Secure the wires covered by the insulation tube with the clamp accessory Be sure to put the part of the sheathed vinyl into the control box Terminal block 4P Conduit Power supply wiring Ground wire Indoor PC board ASSY Cl...

Page 13: ... out the test operation in accordance with the Operation Manual to ensure that all functions and parts are working properly The air conditioner requires a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air cond...

Page 14: ...Two dimensional bar code is a code for manufacturing 3P297301 3C M11B121B 1210 HT 00_CV_3P297301 3C indd 2 10 26 2012 11 23 57 AM ...

Reviews: