background image

7

Names of Parts and Operations

Preparation Before Operation

Read First

Operating/Indicator panel

FAN/MODE button

Press to cycle between FAN settings 

and MODEs.  

 

Page 9-11

ON/OFF button

Press to turn the power ON or OFF. 

 

 

Page 9

1

Positioning the unit

Before installation, peel off the 

tape fixing the power supply 

cord to the bottom of the unit 

and draw out the power supply 

cord.

Power supply cord

Tape (blue)

Pointers for good positioning

•  Choose a position from where airfl ow can reach all areas of the room.
• 

Place on a stable surface. If the unit is placed on an unstable 

surface, vibrations from the unit may be amplifi ed.

•  If you fi nd that interference from the power circuit inside the unit 

or cables causes interference on your TV screen or static noise 
to be emitted from nearby radios or stereos, move the unit to at 

least 2m away from the device.
Keep cordless phones and radio-controlled clocks away from the 

unit also.

Attention

•  To avoid staining of walls, position the unit in accordance with 

the positioning measurements in the illustration. However, note 
that since this unit draws in dirty air, certain types of wall may be 

stained even if the measurements are adhered to.

In such cases, make sure to maintain suffi cient distance 
between the unit and the wall.

• 

When used for a long period of time in the same location, the 

fl oor and surrounding walls may get stained as air is drawn into 

air inlets near the base of the unit. It is recommended to clean 
the unit periodically.

 

At least 100cm 

away from ceiling

At least 30cm 

away from wall

Air fl ow

At least 10cm 

away from wall

At least 30cm 

away from wall

Accessories

Operation manual ....... 1

01_EN_3P484757-1D.indd   7

10/1/2018   11:37:09 AM

Summary of Contents for STREMER MC40UVM6

Page 1: ...ri er Thank you for purchasing this air puri er Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep the operation...

Page 2: ...2 5 m particles 1 Controlling PM2 5 These results were obtained in a 32m airtight space They are not demonstrable effects in customer environments Does not take into account in ow of new particles fr...

Page 3: ...tor Lamp Brightness 11 Advanced Settings Setting Dust PM2 5 Sensor Sensitivity 12 Operation Using the Air Purifying Operation 9 Changing the Airflow Rate 9 Maintenance Maintenance 13 Replacing the Str...

Page 4: ...ating or short circuiting may result if the power supply plug is not firmly inserted Periodically wipe dust off the power supply plug with a dry cloth If the unit is not to be used for an extended per...

Page 5: ...n responsible for their safety Children should be supervised to ensure that they do not play with the appliance Persons who are heavily intoxicated or have taken sleep medication should not operate th...

Page 6: ...5 sensor Inside the air inlet left side Page 6 12 13 Model name Production no Air inlets Front Side Power supply cord Air outlet Power supply plug Main Removable Parts Pre filter Page 13 Outflow grill...

Page 7: ...nt odour level in the first minute after the unit is plugged in serves as the reference level upon which the sensitivity of the odour sensor is determined Insert the power supply plug when the air is...

Page 8: ...e on your TV screen or static noise to be emitted from nearby radios or stereos move the unit to at least 2m away from the device Keep cordless phones and radio controlled clocks away from the unit al...

Page 9: ...s may degrade mechanical parts and lead to malfunction Places with high levels of electromagnetic waves such as near an electromagnetic cooker speakers etc The unit may not function correctly Places e...

Page 10: ...setting be set to Standard or above otherwise deodorising capacity is reduced Turbo The ambient air is quickly purified using a large airflow Recommended for use while you are cleaning up a room Usin...

Page 11: ...during sleep hours 1 By comparison to AUTO FAN MODE approx 9 2Wh power consumption in ECONO MODE approx 6 5Wh is approx 2 7Wh lower Test conditions operation in 10m2 area over 1 hour Assuming 1 cigare...

Page 12: ...on will also switch After switching to the desired brightness press and select FAN setting and MODE of operation again Note This function is useful if the lamps bother you during sleep hours etc The O...

Page 13: ...nsitivity To set sensitivity High Select the FAN lamp Turbo The sensor is highly receptive Setting at time of purchase The sensor is slightly receptive Standard Turbo Low High Normal Low To set sensit...

Page 14: ...bud or hard brush etc Partial breakage of the filter may result Do not apply heavy force Partial breakage damage of the filter may result Removing Grip the indent in the pre filter and pull 1 Grip eit...

Page 15: ...depends on usage patterns and the location of the unit If the unit is used daily in a home where 5 cigarettes are smoked a day the filter should be replaced about every 10 years Calculation based on t...

Page 16: ...is pushed Pulling forcibly may cause damage 2 1 Connector Hook 2 Push in the left side of the streamer unit so the right side comes out You will hear a catching sound 3 Remove the streamer unit 4 Atta...

Page 17: ...ste separation rules when disposing of the dust collection filter made of polyester and polypropylene Maintenance When Not Using the Unit for Long Time Periods 1 Remove the power supply plug 2 Clean t...

Page 18: ...ttached These lamps may blink if the unit is operated without a part attached If all parts are attached An electrical component is faulty Contact the place of purchase If one or more components are no...

Page 19: ...or Q Can the dust collection filter be cleaned A No Do not attempt to clean it with a vacuum cleaner or water Reduced performance of the dust collection filter may result Replace it if dirt buildup is...

Page 20: ...sound during operation While the streamer is operating the streamer unit will emit a hissing sound when conducting streamer discharge Depending on usage conditions the sound may fall in volume or chan...

Page 21: ...dirt from the lens using a dry cotton bud or similar Page 13 Is the pre filter dirty Page 13 Clean these parts After cleaning the unit will return to normal operation a short while after being turned...

Page 22: ...for a short while No air is being emitted Is the air outlet or an air inlet blocked If they are not blocked the fan motor is faulty Contact the place of purchase Other Phenomenon Check points The fan...

Page 23: ...sound dB 49 36 27 19 Airflow rate m h 240 168 108 66 Coverage area m 31 1 External dimensions mm 500 H 270 W 270 D Weight kg 6 8 Power supply cord length m 1 8 These specification values are applicab...