background image

14

English

 WARNING

•  Do not use petrol, benzine, thinner, polishing compound, paraffin, alcohol, etc. (An electric shock, fire, or cracking may result)
•  Do not wash the main body of the unit with water. (An electric shock, fire, or malfunctioning/breakage may result)

Maintenance

Deodorising filter unit

When concerned about odours or dirt  
 

Vacuum clean

 

   Do not use water

•  Remove from the unit together with the frame 

and remove dust using a vacuum cleaner.

•  If odour becomes an issue, wet the surface lightly 

with an atomiser etc., and then leave the part to dry 
in a shaded area with good ventilation. (about 1 day)

• 

Do not scrub the surface.

•  Do not use water when cleaning. (If water is 

used, the part will lose its shape and become 

unusable.)

 

 

Page 18

Removing

Hold the lever and grip of the deodourising filter 

unit and remove.

Lever

Grip

Attaching

Fully insert the deodourising filter unit.

Push until you 

hear a catching 

sound.

•  If the deodourising filter unit is removed or incorrectly 

installed, the odour sensor lamp will blink.

Dust collection filter

About every 10 years  

Replace

    

 

Do not use water    Do not vacuum clean

•  Do not use a vacuum cleaner or use water 

when cleaning.

 

(If the filter is damaged or holes are opened 
etc., dust will pass through the filter and 
capacity for dust collection will be reduced.)

About part replacement timing

•  Replacement timing depends on usage patterns 

and the location of the unit. 

If the unit is used daily in a home where 5 cigarettes 
are smoked a day, the filter should be replaced 

about every 10 years.  (Calculation based on testing 
method of Japan Electrical Manufacturers 
Association JEM1467 standard.) 
If the impurity content of the ambient air is high, the 

filter will need more frequent replacement.

 

If the filter is failing to perform, it is time to replace it.

About purchasing and disposal

•  Refer to “Separately Sold Parts”. 

 

 

Page 16

Removing

1

 Remove the deodorising filter unit.

Dust collection filter

2  Pull the tag 

upward.

3  

Hold the lower part of the dust 
collection filter and lift it out.

Attaching

1

 Install the new dust collection filter, being 

careful of the orientation.

Side with tag and 

markings should face 

outward and arrow should 

point up

2  

Attach the deodorising filter unit.

Do not detach 

the deodorising 

filter from frame

Attention

•  Make sure that the dust collection filter and deodorising filter unit are attached to the unit when the unit is operating.

 

If these parts are not attached when the unit is operated, breakage/malfunctioning may result.

•  Follow the advice below to prevent discolouration or deformation.

 

If detergent was used, make sure to wipe it up thoroughly so none remains.

 

If hot water is used, make sure that it is 40ºC or less.

 

Do not leave parts to dry in direct sunlight.

 

Do not dry parts using a dryer.

 

Do not apply fire to parts. 

• 

If using a vacuum cleaner, make sure to not apply force to or knock the part. (Damage may result)

01_EN_3P484757-1D.indd   14

10/1/2018   11:37:14 AM

Summary of Contents for STREMER MC40UVM6

Page 1: ...ri er Thank you for purchasing this air puri er Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep the operation...

Page 2: ...2 5 m particles 1 Controlling PM2 5 These results were obtained in a 32m airtight space They are not demonstrable effects in customer environments Does not take into account in ow of new particles fr...

Page 3: ...tor Lamp Brightness 11 Advanced Settings Setting Dust PM2 5 Sensor Sensitivity 12 Operation Using the Air Purifying Operation 9 Changing the Airflow Rate 9 Maintenance Maintenance 13 Replacing the Str...

Page 4: ...ating or short circuiting may result if the power supply plug is not firmly inserted Periodically wipe dust off the power supply plug with a dry cloth If the unit is not to be used for an extended per...

Page 5: ...n responsible for their safety Children should be supervised to ensure that they do not play with the appliance Persons who are heavily intoxicated or have taken sleep medication should not operate th...

Page 6: ...5 sensor Inside the air inlet left side Page 6 12 13 Model name Production no Air inlets Front Side Power supply cord Air outlet Power supply plug Main Removable Parts Pre filter Page 13 Outflow grill...

Page 7: ...nt odour level in the first minute after the unit is plugged in serves as the reference level upon which the sensitivity of the odour sensor is determined Insert the power supply plug when the air is...

Page 8: ...e on your TV screen or static noise to be emitted from nearby radios or stereos move the unit to at least 2m away from the device Keep cordless phones and radio controlled clocks away from the unit al...

Page 9: ...s may degrade mechanical parts and lead to malfunction Places with high levels of electromagnetic waves such as near an electromagnetic cooker speakers etc The unit may not function correctly Places e...

Page 10: ...setting be set to Standard or above otherwise deodorising capacity is reduced Turbo The ambient air is quickly purified using a large airflow Recommended for use while you are cleaning up a room Usin...

Page 11: ...during sleep hours 1 By comparison to AUTO FAN MODE approx 9 2Wh power consumption in ECONO MODE approx 6 5Wh is approx 2 7Wh lower Test conditions operation in 10m2 area over 1 hour Assuming 1 cigare...

Page 12: ...on will also switch After switching to the desired brightness press and select FAN setting and MODE of operation again Note This function is useful if the lamps bother you during sleep hours etc The O...

Page 13: ...nsitivity To set sensitivity High Select the FAN lamp Turbo The sensor is highly receptive Setting at time of purchase The sensor is slightly receptive Standard Turbo Low High Normal Low To set sensit...

Page 14: ...bud or hard brush etc Partial breakage of the filter may result Do not apply heavy force Partial breakage damage of the filter may result Removing Grip the indent in the pre filter and pull 1 Grip eit...

Page 15: ...depends on usage patterns and the location of the unit If the unit is used daily in a home where 5 cigarettes are smoked a day the filter should be replaced about every 10 years Calculation based on t...

Page 16: ...is pushed Pulling forcibly may cause damage 2 1 Connector Hook 2 Push in the left side of the streamer unit so the right side comes out You will hear a catching sound 3 Remove the streamer unit 4 Atta...

Page 17: ...ste separation rules when disposing of the dust collection filter made of polyester and polypropylene Maintenance When Not Using the Unit for Long Time Periods 1 Remove the power supply plug 2 Clean t...

Page 18: ...ttached These lamps may blink if the unit is operated without a part attached If all parts are attached An electrical component is faulty Contact the place of purchase If one or more components are no...

Page 19: ...or Q Can the dust collection filter be cleaned A No Do not attempt to clean it with a vacuum cleaner or water Reduced performance of the dust collection filter may result Replace it if dirt buildup is...

Page 20: ...sound during operation While the streamer is operating the streamer unit will emit a hissing sound when conducting streamer discharge Depending on usage conditions the sound may fall in volume or chan...

Page 21: ...dirt from the lens using a dry cotton bud or similar Page 13 Is the pre filter dirty Page 13 Clean these parts After cleaning the unit will return to normal operation a short while after being turned...

Page 22: ...for a short while No air is being emitted Is the air outlet or an air inlet blocked If they are not blocked the fan motor is faulty Contact the place of purchase Other Phenomenon Check points The fan...

Page 23: ...sound dB 49 36 27 19 Airflow rate m h 240 168 108 66 Coverage area m 31 1 External dimensions mm 500 H 270 W 270 D Weight kg 6 8 Power supply cord length m 1 8 These specification values are applicab...

Page 24: ...3P484757 1D M16B358C 1812 HT The two dimensional bar code is a manufacturing code The bar code is a manufacturing code...

Reviews: