![Daikin SM-12-012 Service Manual Download Page 43](http://html1.mh-extra.com/html/daikin/sm-12-012/sm-12-012_service-manual_2459094043.webp)
Service Manual SM-Inverter_(i)
43
L5
Description
IPM error/IGBT error
Supposed Cause
-
Over current due to defective power transistor
-
Over current due to wrong internal wiring
-
Over current due to abnormal supply voltage
-
Over current due to defective PCB
-
Error detection due to defective PCB
-
Over- current due to closed stop valve
-
Over current due to compressor failure
-
Over current due to poor installation condition
-
Connection between main board and IPM board is not properly connect
Troubleshooting
Summary of Contents for SM-12-012
Page 1: ...Service Manual SM Inverter_ i Air Conditioners Service Manual Split Inverter SM 12 012...
Page 22: ...Service Manual SM Inverter_ i 22...
Page 26: ...Service Manual SM Inverter_ i 26...
Page 45: ...Service Manual SM Inverter_ i 45 Troubleshooting...
Page 47: ...Service Manual SM Inverter_ i 47...
Page 50: ...Service Manual SM Inverter_ i 50 ATXN FTXN 50 60 LV1B 9 ARXN RXN50 60 LV1B 9...
Page 51: ...Service Manual SM Inverter_ i 51 Refrigerant Diagram ATXN FTXN 25 35 50 60 LV1B 9...