![Daikin SM-12-012 Service Manual Download Page 16](http://html1.mh-extra.com/html/daikin/sm-12-012/sm-12-012_service-manual_2459094016.webp)
Service Manual SM-Inverter_(i)
16
3.
ID unit buzzer will produce a long beep if the handset error code matched with unit error.
4.
A short and two consecutive beeps is Not the unit error.
5.
The code display will cancel itself if the button is not pressed for 1 minute.
How to Retrieved Last State Error:
1)
Remove battery from remote controller.
2)
Replace battery again into remote controller.
3)
Press Mode & ON/OFF buttons together.
4)
The “ 00 “ will show at temperature section.
5)
Press Mode button to 5:00
6)
Press Power On toward the indoor unit. Unit LED blinks two times indicate received signal.
7)
ON hold fan button till screen become normal display.
8)
Repeat the normal step to retrieve error. (by using remote controller step. Holding TIMER CANCEL…)
9)
By using this method, the error shown will be Last State Error.(Previous error in this unit)
ON/OFF
button
Mode
button
Summary of Contents for SM-12-012
Page 1: ...Service Manual SM Inverter_ i Air Conditioners Service Manual Split Inverter SM 12 012...
Page 22: ...Service Manual SM Inverter_ i 22...
Page 26: ...Service Manual SM Inverter_ i 26...
Page 45: ...Service Manual SM Inverter_ i 45 Troubleshooting...
Page 47: ...Service Manual SM Inverter_ i 47...
Page 50: ...Service Manual SM Inverter_ i 50 ATXN FTXN 50 60 LV1B 9 ARXN RXN50 60 LV1B 9...
Page 51: ...Service Manual SM Inverter_ i 51 Refrigerant Diagram ATXN FTXN 25 35 50 60 LV1B 9...