background image

9

English

3. Adjust Air Flow Direction from the Main Menu.

If the connected indoor unit model does not include
oscillating louvers this function will not be available.

4. When the On/Off Button is pressed again, the system will

stop operating and the operation lamp will turn off.

NOTE: To prevent water damage or system failure, do not
immediately remove power from the indoor unit following
system operation. Wait at least five minutes for the condensate
pump to finish draining residual water from the unit.

CHARACTERISTIC OF DRY MODE

The Dry Mode dehumidifies the space at reduced cooling capacity
to prevent the room temperature from dropping to uncomfortable
levels.

7.  OPTIMUM OPERATION

Observe the following precautions to ensure the system operates:

Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.

Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds. Ventilate the room
regularly. Using the unit for long periods of time requires
attentive ventilation of the room.

Keep doors and windows closed. If the doors and windows
remain open, air will escape and diminish cooling or heating
operation.

Never place objects near the air inlet and the air outlet of the
unit. It may cause deterioration in the effect or stop in the
operation.

Turn off the main power supply switch when it is not used for
long periods of time. When the main power switch is turned
on, some watts of electricity is being used even if the system
is not operating. Turn off the main power supply switch for
saving energy. When reoperating, turn on the main power
supply switch 6 hours before operation for smooth running
(Refer to MAINTENANCE).

When the display shows "Time to clean filter'', ask a qualified
service person to clean the filters (Refer to MAINTENANCE).

8.  MAINTENANCE (FOR SERVICE PERSONNEL)

Only a qualified person is allowed to perform

maintenance without daily maintenance.

Before touching any of the connection wirings, be sure

to turn off all power supply switches.

For installation of optional parts, only a qualifited person

is allowed to do so.

Be sure to use optional parts specified by the manufacturer.

Installation in your own manner may result in water leakage,
electric shock or fire.

Do not use flammable material (e.g. hair-spray or insecticide)

near the product.

Only proceed with the unit cleaning after stopping the

operation and turning the power supply off.

Failure to do so may result in electric shocks or injury.

Do not wash the heat pump or air handler with water.

Failure to do so may result in an electric shock.

Consult with installation contractor for cleaning the

inside of the air handler.

Wrong cleaning procedures may break plastic parts or cause

water leakage or electric shock.

Use a stable prep stand.

Pay extra attention when cleaning the air handler.

Maintenance and Inspection

Clean the drain pan periodically. The drain pipes clogged
with dust will cause water leakage.

For cleaning, consult with your Daikin dealer. (Before each
season when cooling or heating is required, clean the air
conditioner or heat pump.)

If the area around the indoor unit is very dusty, use a dust
proof cover (local procurement).

Cleaning the Inside of the Indoor Unit

It is necessary to clean the inside of the indoor unit
periodically.

Since the cleaning requires special technologies, request a
Daikin dealer to clean them.

Daily Maintenance (Cleaning the Air Filter)

The air filter is field supply.

Summary of Contents for SkyAir FTQ18TAVJUA

Page 1: ...glish Fran ais Espa ol ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL ADJUST SERVICE OR REPAIR HEREINAFTER SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD SERVICE THE EQUIPMENT THE MANUFACTURE...

Page 2: ...ck hazard resulting in severe injury or death Additionally grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death If refrigerant gas leaks during installa...

Page 3: ...gloves Install drain piping to proper drainage Improper drain piping may result in water leakage and property damage Insulate piping to prevent condensation Be careful when transporting the product D...

Page 4: ...conventional refrigerants gauge manifold charge hose gas leak detector reverse flow check valve refrigerant charge base vacuum gauge or refrigerant recovery equipment If the conventional refrigerant a...

Page 5: ...ler Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this...

Page 6: ...on is pressed continuously Used to change the selected item 6 Right Button Used to highlight items to the right of the currently selected item Display contents are changed to next screen per page 7 Le...

Page 7: ...How to follow the operation manual Preparation For mechanical protection purposes apply power to the outdoor units at least six hours before starting the opeartion of the system Operation 1 Press the...

Page 8: ...ystem automatically controls the following operating modes to prevent the reduction of heating capacity and space comfort Defrost Operation The system will automatically go into defrost operation to p...

Page 9: ...y switch 6 hours before operation for smooth running Refer to MAINTENANCE When the display shows Time to clean filter ask a qualified service person to clean the filters Refer to MAINTENANCE 8 MAINTEN...

Page 10: ...e time to clean filter and how to clean please refer to the attached manual HOW TO CLEAN THE AIR FILTER 1 Remove the air filter 2 Clean the air filter Please refer to attached manual Air filter is fie...

Page 11: ...immediately after the ON OFF button is pressed If the OPERATION lamp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of t...

Page 12: ...TING I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person If the air conditioner or heat...

Page 13: ...if If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle to ensure it is well ventilated If the air filter is clogged Ask a qualified service pers...

Page 14: ...14 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 15: ...15 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 16: ...and drain pan tablets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum e...

Reviews: