EXPLANATION:

Removing the air filter except when cleaning the air
conditioner or heat pump may result in accidents.

When it is time to clean or replace the filter, the “Time to
Clean Filter” message will appear on the bottom of the basic
screen.

Wash, clean, or replace the filter or element.

If using the air conditioner or heat pump under a very dusty
environment, increase the frequency of air filter cleaning.

Consult a dealer to change filter setting time to display filter
change alarm on remote controller screen. (The default
factory setting is 2500 hours.)

There are the following time display patterns: 1250, 2500,
5000, 10000.

Air filter is field suppply. In the time to clean filter and how to
clean, please refer to the attached manual.

HOW TO CLEAN THE AIR FILTER

1. Remove the air filter.

2. Clean the air filter. Please refer to attached manual. (Air

filter is field supply.) Use a vacuum cleaner 

(A)

 or wash the

air filter with water 

(B)

.

A) Using a vacuum cleaner

B) Washing With Water - When the air filter is very dirty, use
soft brush and neutral detergent. Remove water and dry in
the shade.

NOTE: Do NOT wash the air filter with hot water. Doing so may
result in discoloration and/or deformation.

NOTE: Do NOT expose air filter to fire. Doing so may result in
burning.

3. Attach the air filter.

Once cleaning is done, be sure to replace the air filter
as it was.

Reset the filter indicator when the filter is cleaned or
replaced.

Press Menu/OK button. The Main Menu screen will
appear.

4. Push the “Filter Sign Reset” button on the remote controller.

Summary of Contents for SkyAir FTQ18TAVJUA

Page 1: ...glish Fran ais Espa ol ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL ADJUST SERVICE OR REPAIR HEREINAFTER SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD SERVICE THE EQUIPMENT THE MANUFACTURE...

Page 2: ...ck hazard resulting in severe injury or death Additionally grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death If refrigerant gas leaks during installa...

Page 3: ...gloves Install drain piping to proper drainage Improper drain piping may result in water leakage and property damage Insulate piping to prevent condensation Be careful when transporting the product D...

Page 4: ...conventional refrigerants gauge manifold charge hose gas leak detector reverse flow check valve refrigerant charge base vacuum gauge or refrigerant recovery equipment If the conventional refrigerant a...

Page 5: ...ler Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this...

Page 6: ...on is pressed continuously Used to change the selected item 6 Right Button Used to highlight items to the right of the currently selected item Display contents are changed to next screen per page 7 Le...

Page 7: ...How to follow the operation manual Preparation For mechanical protection purposes apply power to the outdoor units at least six hours before starting the opeartion of the system Operation 1 Press the...

Page 8: ...ystem automatically controls the following operating modes to prevent the reduction of heating capacity and space comfort Defrost Operation The system will automatically go into defrost operation to p...

Page 9: ...y switch 6 hours before operation for smooth running Refer to MAINTENANCE When the display shows Time to clean filter ask a qualified service person to clean the filters Refer to MAINTENANCE 8 MAINTEN...

Page 10: ...e time to clean filter and how to clean please refer to the attached manual HOW TO CLEAN THE AIR FILTER 1 Remove the air filter 2 Clean the air filter Please refer to attached manual Air filter is fie...

Page 11: ...immediately after the ON OFF button is pressed If the OPERATION lamp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of t...

Page 12: ...TING I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person If the air conditioner or heat...

Page 13: ...if If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle to ensure it is well ventilated If the air filter is clogged Ask a qualified service pers...

Page 14: ...14 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 15: ...15 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 16: ...and drain pan tablets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum e...