AIR HANDLER

AIR HANDLER HOMEOWNER’S

 

ROUTINE MAINTENANCE RECOMMENDATIONS

We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a 

qualified servicer

.

REPLACE OR CLEAN FILTER

IMPORTANT NOTE: 

Never operate unit without a filter installed as dust and lint will build up on internal parts resulting in loss of efficiency,

equipment damage and possible fire.
An indoor air filter must be used with your comfort system. A properly maintained filter will keep the indoor coil of your comfort system clean.
A dirty coil could cause poor operation and/or severe equipment damage.
Your air filter or filters could be located in your furnace, in a blower unit, or in “filter grilles” in your ceiling or walls. The installer of your air
conditioner or heat pump can tell you where your filter(s) are, and how to clean or replace them.
Check your filter(s) at least once a month. When they are dirty, replace or clean as required. Disposable type filters should be replaced.
Reusable type filters may be cleaned.
You may want to ask your dealer about high efficiency filters. High efficiency filters are available in both electronic and non-electronic types.
These filters can do a better job of catching small airborne particles.

MOTOR

S

Indoor and outdoor fan motors are permanently lubricated and do not
require additional oiling.

ALUMINUM INDOOR COIL CLEANING
(QUALIFIED SERVICER ONLY)

This unit is equipped with an aluminum tube evaporator coil. The safest
way to clean the evaporator coil is to simply flush the coil with water. This
cleaning practice remains as the recommended cleaning method for both copper tube and aluminum tube residential evaporator  coils.
It has been determined that many coil cleaners and drain pan tablets contain corrosive chemicals that can be harmful to aluminum tube and
fin evaporator coils. Even a one-time application of these corrosive chemicals can cause premature aluminum evaporator coil failure. Any
cleaners that contain corrosive chemicals including, but not limited to, chlorine and hydroxides, should not be used.
An alternate cleaning method is to use one of the products listed in TP-109* to clean the coils. The cleaners listed are the only agents deemed
safe and approved for use to clean round tube aluminum coils. TP-109 is also available on the web site in Partner Link > Service Toolkit.
NOTE: Ensure coils are rinsed well after use of any chemical cleaners.

BEFORE YOU CALL YOUR SERVICER

Check the controller to confirm that it is properly set.

Wait 15 minutes. Some devices in the outdoor unit or in programmable
controllers will prevent compressor operation for awhile, and then
reset automatically. Also, some power companies will install devices
which shut off air conditioners for several minutes on hot days. If you
wait several minutes, the unit may begin operation on its own.

Check the electrical panel  for tripped circuit breakers  or failed fuses.
Reset the circuit breakers or replace fuses as necessary.

Check the disconnect switch near the indoor furnace or blower to
confirm that it is closed.

Check for obstructions on the outdoor unit . Confirm that it has not been covered on the sides or the top. Remove any obstruction that can
be safely  removed. If  the unit is covered with dirt or debris, call a qualified servicer to clean it.

Check for blockage of the indoor air inlets and outlets. Confirm that they are open and have not been blocked by objects (rugs, curtains or
furniture).

Check the filter. If it is dirty, clean or replace it.

Listen for any unusual noise(s), other than normal operating noise, that might be coming from the outdoor unit.   If you hear unusual
noise(s) coming from the unit, call a qualified servicer.

Summary of Contents for SkyAir FTQ18TAVJUA

Page 1: ...glish Fran ais Espa ol ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL ADJUST SERVICE OR REPAIR HEREINAFTER SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD SERVICE THE EQUIPMENT THE MANUFACTURE...

Page 2: ...ck hazard resulting in severe injury or death Additionally grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death If refrigerant gas leaks during installa...

Page 3: ...gloves Install drain piping to proper drainage Improper drain piping may result in water leakage and property damage Insulate piping to prevent condensation Be careful when transporting the product D...

Page 4: ...conventional refrigerants gauge manifold charge hose gas leak detector reverse flow check valve refrigerant charge base vacuum gauge or refrigerant recovery equipment If the conventional refrigerant a...

Page 5: ...ler Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this...

Page 6: ...on is pressed continuously Used to change the selected item 6 Right Button Used to highlight items to the right of the currently selected item Display contents are changed to next screen per page 7 Le...

Page 7: ...How to follow the operation manual Preparation For mechanical protection purposes apply power to the outdoor units at least six hours before starting the opeartion of the system Operation 1 Press the...

Page 8: ...ystem automatically controls the following operating modes to prevent the reduction of heating capacity and space comfort Defrost Operation The system will automatically go into defrost operation to p...

Page 9: ...y switch 6 hours before operation for smooth running Refer to MAINTENANCE When the display shows Time to clean filter ask a qualified service person to clean the filters Refer to MAINTENANCE 8 MAINTEN...

Page 10: ...e time to clean filter and how to clean please refer to the attached manual HOW TO CLEAN THE AIR FILTER 1 Remove the air filter 2 Clean the air filter Please refer to attached manual Air filter is fie...

Page 11: ...immediately after the ON OFF button is pressed If the OPERATION lamp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of t...

Page 12: ...TING I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person If the air conditioner or heat...

Page 13: ...if If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle to ensure it is well ventilated If the air filter is clogged Ask a qualified service pers...

Page 14: ...14 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 15: ...15 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 16: ...and drain pan tablets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum e...

Reviews: