When the system is changed over to HEATING
OPERATION after DEFROST OPERATION.

 Moisture

generated by DEFROST becomes steam.

IV. NOISE OF HEAT PUMP

A ringing sound after the unit is started. 

This sound is

generated by the temperature regulator working. It will quiet
down after about a minute.

A continuous "Whoosh" is heard when the system is in
COOLING or DEFROST OPERATION. 

This is the sound

of refrigerant gas flowing through both indoor and outdoor
units.

A "Whoosh" sound Is heard at the start or immediately
after the stop of operation and at the start or immediately
after the stop of DEFROST OPERATION. 

This is the noise

of refrigerant caused by flow stop and flow change.

A continuous flow "Whoosh" sound is heard when the
system is in COOLING OPERATION or at a stop. 

The

noise ls heard when the drain pump is in operation.

V. DUST FROM THE UNITS

Dust may blow out from the unit after starting operation
after not being used for a while.

 Dust absorbed by the

unit blows out.

VI. THE UNITS GIVE OFF ODORS

The unit absorbs the smell of rooms, furniture, cigarettes,
etc., and then emits them .

VII. THE LIQUID CRYSTAL OFTHE REMOTE CONTROLLER

DISPLAY “Checking the connection. Please stand by"

This occurs immediately after the main power supply
switch is turned on.

 This indicates that the remote controller

is in normal condition and continues temporarily.

10.  TROUBLE SHOOTING

I.

If one of the following malfunctions occurs, take the
measures shown below and contact your Daikin dealer.

The system must be repaired by a qualified service person.

If the air conditioner or heat pump is operating abnormally, such
as a burning smell, unplug the power cord from the outlet, and
contact your dealer.

Continued operation under such circumstances may result in a
failure, electric shock, and fire.

If a safety device such as a fuse, a breaker or an ground
leakage breaker frequently actuates:

Procedure:

 Do not turn on the main power switch, take the

following actions.

If the ON/OFF switch does not properly work:

Procedure:

 Turn off the main power switch

If water leaks from unit:

Procedure:

 Stop the operation.

If an error occurs, either one of the following items will flash
in the basic screen.

"Error: Push Menu button"

 - The operation lamp will flash.

“Warning: Push Menu button”

 - The operation lamp will

not flash.

Press Menu/OK button.

The error code will flash and the service contact and model
name or code may appear.

Notify your Daikin dealer of the Error code and model name
or code.

II. If the system does not properly operate (except for the

above mentioned case), and none of the other mentioned
malfunctions are evident, investigate the system
according to the following procedures:

1. If the system does not operate at all.

Check if there is a power failure. Wait until power is
restored. If a power failure occurs during operation, the
system automatically restarts immediately after the
power supply recovers.

Check if a fuse has blown. Turn off the power supply.

Summary of Contents for SkyAir FTQ18TAVJUA

Page 1: ...glish Fran ais Espa ol ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL ADJUST SERVICE OR REPAIR HEREINAFTER SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD SERVICE THE EQUIPMENT THE MANUFACTURE...

Page 2: ...ck hazard resulting in severe injury or death Additionally grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death If refrigerant gas leaks during installa...

Page 3: ...gloves Install drain piping to proper drainage Improper drain piping may result in water leakage and property damage Insulate piping to prevent condensation Be careful when transporting the product D...

Page 4: ...conventional refrigerants gauge manifold charge hose gas leak detector reverse flow check valve refrigerant charge base vacuum gauge or refrigerant recovery equipment If the conventional refrigerant a...

Page 5: ...ler Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this...

Page 6: ...on is pressed continuously Used to change the selected item 6 Right Button Used to highlight items to the right of the currently selected item Display contents are changed to next screen per page 7 Le...

Page 7: ...How to follow the operation manual Preparation For mechanical protection purposes apply power to the outdoor units at least six hours before starting the opeartion of the system Operation 1 Press the...

Page 8: ...ystem automatically controls the following operating modes to prevent the reduction of heating capacity and space comfort Defrost Operation The system will automatically go into defrost operation to p...

Page 9: ...y switch 6 hours before operation for smooth running Refer to MAINTENANCE When the display shows Time to clean filter ask a qualified service person to clean the filters Refer to MAINTENANCE 8 MAINTEN...

Page 10: ...e time to clean filter and how to clean please refer to the attached manual HOW TO CLEAN THE AIR FILTER 1 Remove the air filter 2 Clean the air filter Please refer to attached manual Air filter is fie...

Page 11: ...immediately after the ON OFF button is pressed If the OPERATION lamp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of t...

Page 12: ...TING I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person If the air conditioner or heat...

Page 13: ...if If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle to ensure it is well ventilated If the air filter is clogged Ask a qualified service pers...

Page 14: ...14 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 15: ...15 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 16: ...and drain pan tablets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum e...

Reviews: