The following symptoms do not indicate air conditioner malfunc-
tion

I.

THE SYSTEM DOES NOT OPERATE

• The system does not restart immediately after the ON/

OFF button is pressed.

If the OPERATION lamp lights, the system is in normal con-
dition.
It does not restart immediately because a safety device 
operates to prevent overload of the system. After 3 minutes, 
the system will turn on again automatically.

• The system does not restart immediately when TEM-

PERATURE SETTING button is returned to the former 
position after pushing the button.

If the OPERATION lamp lights, the system is in normal con-
dition.
It does not restart immediately because a safety device 
operates to prevent overload of the system. After 3 minutes, 
the system will turn on again automatically.

• The system does not start when the display shows 

” and it flashes for a few seconds after pressing 

an operation button.

This is because the system is under centralized control. 
Flashes on the display indicates that the system cannot be 
controlled by the remote controller.

• The system does not start immediately after the power 

supply is turned on.

Wait one minute until the micro computer is prepared for 
operation.

II. WHITE MIST COMES OUT OF A UNIT

• When humidity is high during cooling operation. (In 

oily or dusty places)

If the inside of an indoor unit is extremely contaminated, the 
temperature distribution inside a room becomes uneven. It 
is necessary to clean the inside of the indoor unit. Ask your 
Daikin dealer for details on cleaning the unit. This operation 
requires a qualified service person.

• When the system is changed over to HEATING OPERA-

TION after DEFROST OPERATION.

Moisture generated by DEFROST becomes steam and 
exists.

III. NOISE OF AIR CONDITIONERS

• A ringing sound after the unit is started.

This sound is generated by the temperature regulator 
working. 
It will quiet down after about a minute.

• A continuous flow “Shuh” sound is heard when the 

systems is in COOLING or DEFROST OPERATION.

This is the sound of refrigerant gas flowing through both 
indoor and outdoor units.

• A “Shuh” sound which is heard at the start or immedi-

ately after the stop of operation or which is heard at the 
start or immediately after the stop of DEFROST OPER-
ATION.

This is the noise of refrigerant caused by flow stop and flow 
change.

• A continuous low “Shah” sound is heard when the sys-

tem is in COOLING OPERATION or at a stop.

The noise is heard when the drain pump is in operation.

• A “Pishi-pishi” squeaking sound is heard when the 

system is in operation or after the stop of operation.

Expansion and contraction of plastic parts caused by tem-
perature change makes this noise.

IV. DUST FROM THE UNITS

• Dust may blow out from the unit after starting operation 

from long resting time.

Dust absorbed by the unit blows out.

V. THE UNITS GIVE OFF ODORS

The unit absorbs the smell of rooms, furniture, cigarettes, 
etc., and then emits them.

I. If one of the following malfunctions occurs, take 

the measures shown below and contact your 
Daikin dealer.

The system must be repaired by a qualified service person.

WARNING

When the air conditioner is in abnormal condi-
tions (smell of something burning, etc), turn off 
the power supply, and contact your dealer

Continued operation under such circumstances may result in 
a failure, electric shock or fire.

• If a safety device such as a fuse, a breaker or a ground fault 

circuit interrupter frequently actuates; 

Measure:

  Do not turn on the main power switch.

• If the ON/OFF switch does not properly work;

Measure:

  Turn off the main power switch.

• If water leaks from unit.

Measure:

  Stop the operation.

Measure:

Notify your Daikin dealer and inform him/her of the 
display.

8. NOT MALFUNCTION OF THE AIR 

CONDITIONER

CENTRAL

CONTROL

9. TROUBLE SHOOTING

If an error occurs, either one of the follow-
ing items will flash in the basic screen.

“Error: Push Menu button”

*  The operation lamp will flash.

“Warning: Push Menu button”

* The operation lamp will not flash.

When pressing Menu/OK button, the error code will flash 
and the service contact and model name or code may 
appear.

Cool

Set to 

Cool

74

F

Error : Press Menu button

Operation

 lamp

Error code AI

Contact Info
0123-456-7890

Indoor Model

---/000

Outdoor Model

---/000

01_EN_3PN07753-16V.fm  Page 6  Thursday, September 15, 2011  7:13 PM

Summary of Contents for SkyAir FBQ18PVJU

Page 1: ...l should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel à portée de main pour référence ultérieure Ce manuel doit être donné au propriétaire de l équipement Lea cuidadosamente estas instrucciones antes de instalar Guarde este manual en un lugar a mano para leer en caso de tener alguna duda Este manual debe permanecer con el propietario...

Page 2: ...i q g m l k j a f n d e h e b d p RZQ36 42 RZR36 42 RZQ18 24 30 RZR18 24 30 c 1 00_CV_3PN07753 16V fm Page 2 Thursday September 15 2011 6 14 PM ...

Page 3: ... your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units The unit is individually operated NOTE Contact your Daikin dealer in case of changing the combina t...

Page 4: ...ric shock and fire Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a profes sional Contact your dealer to move and reinstall the air condi tioner Incomplete installation may result in water leak age electric shock and fire Never let the indoor unit or the remote controller get wet Water can cause an electric shock or a fire N...

Page 5: ...e heat Do not expose the controller to direct sunlight The LCD display can become discolored and may fail to display the data Do not wipe the controller operation panel with benzene thinner chemical dust cloth etc The panel may get dis colored or the coating can peel off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Then wipe it wit...

Page 6: ... the air conditioner and then consult your dealer or our service station Read the operation manual that came with the remote controller Operating procedure varies with heat pump type and cooling only type Contact your Daikin dealer to confirm your system type To protect the unit turn on the main power switch 6 hours before operation If the main power supply is turned off during operation oper atio...

Page 7: ...andard equip ment Do not install any object other than a proper air filter in the suction inlet for example a paper towel Doing so may result in degraded performance and cause freezing or water leakage 1 Select Reset Filter Indicator on the main menu screen and press Menu Enter button after the air filter is cleaned and attached The Time to clean filter message will be turned OFF Refer to the oper...

Page 8: ...g through both indoor and outdoor units A Shuh sound which is heard at the start or immedi ately after the stop of operation or which is heard at the start or immediately after the stop of DEFROST OPER ATION This is the noise of refrigerant caused by flow stop and flow change A continuous low Shah sound is heard when the sys tem is in COOLING OPERATION or at a stop The noise is heard when the drai...

Page 9: ... clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not sufficiently cool or heat If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle and make it well ventilated If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE If the se...

Page 10: ...1645 Wallace Drive Suite 110 Carrollton TX 75006 USA info daikinac com www daikinac com 1109 3PN07753 16V EM11A058 HT 00_CV_3PN07753 16V fm Page 4 Thursday September 15 2011 6 14 PM ...

Reviews: