background image

4

English

If the temperature or the humidity is beyond the following condi-
tions, safety devices may work and the air conditioner may not 
operate, or sometimes, water may drop from the indoor unit.

DB:  Dry bulb temperature (°F)
WB: Wet bulb temperature (°F)

The setting temperature range of the remote controller is 60°F 
to 90°F.

Regarding places for installation

• Is the air conditioner installed at a well-ventilated place 

where there are no obstacles around?

• Do not use the air conditioner in the following places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring resort
d. Where there are considerable voltage fluctuations such as     

a factory or plant

e. Vehicles and vessels

f. Where there is much spray of oil and vapor such as a 

    cookery, etc.

g. Where there are machines generating electromagnetic     

waves

h. Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

• All wiring must be performed by an authorized electri-

cian.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply circuit is pro-

vided for this air conditioner and that all electrical work 
is carried out by qualified personnel according to local 
laws and regulations.

Pay attention to running noises, too

• Are the following places selected?

a. A place that can sufficiently withstand the weight of the air 
    conditioner with less running noises and vibrations.
b. A place where the hot wind discharged from the air outlet 
    of the outdoor unit and the running noises.

• Are you sure that there are no obstacles near the air out-

let of the outdoor unit?

Such obstacles may result in declined performance and 
increased running noises.

• If abnormal noises occur in use, consult your dealer.

Regarding drainage of drain pipe

• Is the drain pipe executed to perform complete drain-

age?

If proper drainage is not carried out from the outdoor drain 
pipes during air-conditioning operation, chances are that 
dust and dirt are clogged in the pipe. This may result in a 
water leakage from the indoor unit. Under such circum-
stances, stop the operation of the air conditioner, and then 
consult your dealer or our service station.

Read the operation manual that came with the 
remote controller.

• Operating procedure varies with heat pump type and cooling 

only type. Contact your Daikin dealer to confirm your system 
type.

• To protect the unit, turn on the main power switch 6 hours 

before operation.

• If the main power supply is turned off during operation, oper-

ation will restart automatically after the power turns back on 
again.

Observe the following precautions to ensure the system oper-
ates.

• Adjust the room temperature properly for a comfortable envi-

ronment. Avoid excessive heating or cooling.

• Prevent direct sunlight from entering a room during cooling 

operation by using curtains or blinds.

• Ventilate the room regularly.

Using the unit for long periods of time requires attentive ven-
tilation of the room.

• Keep doors and windows closed. If the doors and windows 

remain open, room air will flow out and cause to decrease the 
effect of cooling and heating.

• Do not place other heaters directly below the indoor unit.

They may deform due to the heat.

• Never place objects near the air inlet and the air outlet of the 

unit. It may cause deterioration in the effect or stop in the 
operation.

• Turn off the main power supply switch when it is not used for 

long periods of time. When the main power switch is turned 
on, some watts of electricity is being used even if the system 
is not operating. Turn off the main power supply switch for 
saving energy. When reoperating, turn on the main power 
supply switch 6 hours before operation for smooth running 
(Refer to MAINTENANCE).

• When the display shows “Time to clean filter” ask a qualified 

service person to clean the filter (Refer to MAINTENANCE).

• Fully use the function of airflow direction adjust.

Cold air gathers on the floor, and warm air gathers in the ceil-
ing.
Set the airflow direction parallel during cooling or dry opera-
tion, and set it downwards during heating operation.
Do not let the air blow directly to a person.

• It takes time for the room temperature to reach the set tem-

perature.
We recommend starting the operation in advance using timer 
operation.

3. OPERATION RANGE

OPERATION

TEMPERATURE (°F)

OUTDOOR

INDOOR

COOLING

23 to 115 (DB)

57 to 77 (WB)

HEATING

0 to 60 (WB)

59 to 80.5 (DB)

4. INSTALLATION SITE

5. OPERATION PROCEDURE

6. OPTIMUM OPERATION

01_EN_3PN07753-16V.fm  Page 4  Thursday, September 15, 2011  7:13 PM

Summary of Contents for SkyAir FBQ18PVJU

Page 1: ...l should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel à portée de main pour référence ultérieure Ce manuel doit être donné au propriétaire de l équipement Lea cuidadosamente estas instrucciones antes de instalar Guarde este manual en un lugar a mano para leer en caso de tener alguna duda Este manual debe permanecer con el propietario...

Page 2: ...i q g m l k j a f n d e h e b d p RZQ36 42 RZR36 42 RZQ18 24 30 RZR18 24 30 c 1 00_CV_3PN07753 16V fm Page 2 Thursday September 15 2011 6 14 PM ...

Page 3: ... your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units The unit is individually operated NOTE Contact your Daikin dealer in case of changing the combina t...

Page 4: ...ric shock and fire Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a profes sional Contact your dealer to move and reinstall the air condi tioner Incomplete installation may result in water leak age electric shock and fire Never let the indoor unit or the remote controller get wet Water can cause an electric shock or a fire N...

Page 5: ...e heat Do not expose the controller to direct sunlight The LCD display can become discolored and may fail to display the data Do not wipe the controller operation panel with benzene thinner chemical dust cloth etc The panel may get dis colored or the coating can peel off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Then wipe it wit...

Page 6: ... the air conditioner and then consult your dealer or our service station Read the operation manual that came with the remote controller Operating procedure varies with heat pump type and cooling only type Contact your Daikin dealer to confirm your system type To protect the unit turn on the main power switch 6 hours before operation If the main power supply is turned off during operation oper atio...

Page 7: ...andard equip ment Do not install any object other than a proper air filter in the suction inlet for example a paper towel Doing so may result in degraded performance and cause freezing or water leakage 1 Select Reset Filter Indicator on the main menu screen and press Menu Enter button after the air filter is cleaned and attached The Time to clean filter message will be turned OFF Refer to the oper...

Page 8: ...g through both indoor and outdoor units A Shuh sound which is heard at the start or immedi ately after the stop of operation or which is heard at the start or immediately after the stop of DEFROST OPER ATION This is the noise of refrigerant caused by flow stop and flow change A continuous low Shah sound is heard when the sys tem is in COOLING OPERATION or at a stop The noise is heard when the drai...

Page 9: ... clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not sufficiently cool or heat If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle and make it well ventilated If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE If the se...

Page 10: ...1645 Wallace Drive Suite 110 Carrollton TX 75006 USA info daikinac com www daikinac com 1109 3PN07753 16V EM11A058 HT 00_CV_3PN07753 16V fm Page 4 Thursday September 15 2011 6 14 PM ...

Reviews: