background image

2

English

Read these 

Safety Considerations for Operations

 carefully 

before installing air conditioning equipment. After completing 
the installation, make sure that the unit operates properly during 
the startup operation. Instruct the customer on how to operate 
and maintain the unit.
Inform customers that they should store this Operation Manual 
with the Installation Manual for future reference.
Meanings of 

DANGER

WARNING

CAUTION

, and 

NOTE

 

Symbols:

DANGER

.......... Indicates an imminently hazardous situa-

tion which, if not avoided, will result in 
death or serious injury.

WARNING

......... Indicates a potentially hazardous situation 

which, if not avoided, could result in death 
or serious injury.

CAUTION

.......... Indicates a potentially hazardous situation 

which, if not avoided, may result in minor 
or moderate injury. It may also be used to 
alert against unsafe practices.

NOTE

................ Indicates situations that may result in 

equipment or property-damage accidents 
only.

DANGER

• Do not install the unit in an area where flammable mate-

rials are present due to risk of explosion resulting in 
serious injury or death.

• Any abnormalities in the operation of the air conditioner 

such as smoke or fire could result in severe injury or 
death. Turn off the power and contact your dealer imme-
diately.

• Refrigerant gas may produce toxic gas if it come in con-

tact with fire, such as from a fan, heater, stove, or cook-
ing device. Exposure to this gas could cause severe 
injury or death.

• For refrigerant leakage, consult your dealer.

Refrigerant gas is heavier than air and replaces oxygen. 
A massive leak could lead to oxygen depletion, espe-
cially in basements, and an asphyxiation hazard could 
occur leading to serious injury or death.

• If equipment utilizing a burner is used in the same room 

as the air conditioner, there is the danger of oxygen defi-
ciency which could lead to an asphyxiation hazard 
resulting in serious injury or death. Be sure to ventilate 
the room sufficiently to avoid this hazard.

• Safely dispose of the packing materials. Packing materi-

als, such as nails and other metal or wooden parts, may 
cause stabs or other injuries.

• Tear apart and throw away plastic packaging bags so 

that children will not play with them.
Children playing with plastic bags face the danger of 
death by suffocation.

WARNING

• Contact your dealer for repair and maintenance. 

Improper repair and maintenance may result in water 
leakage, electric shock, and fire. Only use accessories 
made by Daikin that are specifically designed for use 
with the equipment and have them installed by a profes-
sional.

• Contact your dealer to move and reinstall the air condi-

tioner. Incomplete installation may result in water leak-
age, electric shock, and fire.

• Never let the indoor unit or the remote controller get wet. 

Water can cause an electric shock or a fire.

• Never use flammable spray such as hair spray, lacquer, 

or paint near the unit. Flammable spray may cause a fire.

• When a fuse blows out, never replace it with one of 

incorrect ampere ratings or different wires. Always 
replace any blown fuse with a fuse of the same specifi-
cation.

• Never remove the fan guard of the unit. A fan rotating at 

high speed without the fan guard is very dangerous.

• Never inspect or service the unit by yourself. Contact a 

qualified service person to perform this work.

• Turn off all electrical power before doing any mainte-

nance to avoid the risk of serious electric shock; never 
sprinkle or spill water or liquids on the unit.

• Do not touch the switch with wet fingers.

Touching a switch with wet fingers can cause electric 
shock.

• Do not allow children to play on or around the unit to pre-

vent injury.

• The heat exchanger fins are sharp enough to cut. To 

avoid injury wear gloves or cover the fins while working 
around them.

• Do not put a finger or other objects into the air inlet or air 

outlet. The fan is rotating at high speed and will cause 
injury.

• Check the unit foundation for damage on a continuous 

basis, especially if it has been in use for a long time. If 
left in a damaged condition the unit may fall and cause 
injury.

• Placing a flower vase or other containers with water or 

other liquids on the unit could cause a shock or fire if a 
spill occurs.

• Do not touch the air outlet or horizontal blades while the 

swing flap is in operation because fingers could get 
caught and injured.

• Never touch the internal parts of the controller. Do not 

remove the front panel because some parts inside are 
dangerous to touch. To check and adjust internal parts, 
contact your dealer.

• Be sure to establish a ground.

Do not ground the unit to a utility pipe, arrester, or tele-
phone ground. Incomplete grounding may cause electri-
cal shock, or fire. A high surge current from lightning or 
other sources may cause damage to the air conditioner.

• Be sure to install a ground fault circuit interrupter.

Failure to install a ground fault circuit interrupter may 
result in electric shocks, or fire.

2. SAFETY CONSIDERATIONS

01_EN_3PN07753-16V.fm  Page 2  Thursday, September 15, 2011  7:13 PM

Summary of Contents for SkyAir FBQ18PVJU

Page 1: ...l should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel à portée de main pour référence ultérieure Ce manuel doit être donné au propriétaire de l équipement Lea cuidadosamente estas instrucciones antes de instalar Guarde este manual en un lugar a mano para leer en caso de tener alguna duda Este manual debe permanecer con el propietario...

Page 2: ...i q g m l k j a f n d e h e b d p RZQ36 42 RZR36 42 RZQ18 24 30 RZR18 24 30 c 1 00_CV_3PN07753 16V fm Page 2 Thursday September 15 2011 6 14 PM ...

Page 3: ... your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units The unit is individually operated NOTE Contact your Daikin dealer in case of changing the combina t...

Page 4: ...ric shock and fire Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a profes sional Contact your dealer to move and reinstall the air condi tioner Incomplete installation may result in water leak age electric shock and fire Never let the indoor unit or the remote controller get wet Water can cause an electric shock or a fire N...

Page 5: ...e heat Do not expose the controller to direct sunlight The LCD display can become discolored and may fail to display the data Do not wipe the controller operation panel with benzene thinner chemical dust cloth etc The panel may get dis colored or the coating can peel off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Then wipe it wit...

Page 6: ... the air conditioner and then consult your dealer or our service station Read the operation manual that came with the remote controller Operating procedure varies with heat pump type and cooling only type Contact your Daikin dealer to confirm your system type To protect the unit turn on the main power switch 6 hours before operation If the main power supply is turned off during operation oper atio...

Page 7: ...andard equip ment Do not install any object other than a proper air filter in the suction inlet for example a paper towel Doing so may result in degraded performance and cause freezing or water leakage 1 Select Reset Filter Indicator on the main menu screen and press Menu Enter button after the air filter is cleaned and attached The Time to clean filter message will be turned OFF Refer to the oper...

Page 8: ...g through both indoor and outdoor units A Shuh sound which is heard at the start or immedi ately after the stop of operation or which is heard at the start or immediately after the stop of DEFROST OPER ATION This is the noise of refrigerant caused by flow stop and flow change A continuous low Shah sound is heard when the sys tem is in COOLING OPERATION or at a stop The noise is heard when the drai...

Page 9: ... clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not sufficiently cool or heat If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle and make it well ventilated If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE If the se...

Page 10: ...1645 Wallace Drive Suite 110 Carrollton TX 75006 USA info daikinac com www daikinac com 1109 3PN07753 16V EM11A058 HT 00_CV_3PN07753 16V fm Page 4 Thursday September 15 2011 6 14 PM ...

Reviews: