background image

7 Maintenance and service

Operation manual

15

ATXM20~3 ATXM5 ATXM20~35R5V1B
Daikin room air conditioner
3P485919-12S – 2020.06

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner,  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

▪ As an end user, you may NEVER clean inside parts of

the unit by yourself; this work must be performed by a
qualified service person. Contact your dealer.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

7.3

To clean the front panel

1

Clean the front panel with a soft cloth. If it is difficult to remove
stains, use water or a neutral detergent.

7.4

To remove the front panel

1

Hold the front panel by the panel tabs on both sides and open
it.

2

Remove  the  front  panel  by  sliding  it  to  the  left  or  the  right  and
pulling it toward you.

Result: 

The front panel shaft on 1 side will be disconnected.

3

Disconnect  the  front  panel  shaft  on  the  other  side  in  the  same
manner.

a

a

Front panel shaft

7.5

To clean the air filters

1

Push the tab at the centre of each air filter, then pull it down.

2

Pull out the air filters.

2

1

Note:    (class  50) 

The  titanium  apatite  deodorising  filter  and  the

silver  allergen  removal  air  purifying  filter  MUST  be  removed  before
cleaning the air filter.

3

Remove  the  titanium  apatite  deodorising  filter  and  the  silver
allergen removal air purifying filter from all 4 claws.

a

Claw

4

Wash  the  air  filters  with  water  or  clean  them  with  a  vacuum
cleaner.

5

Soak in lukewarm water for about 10 to 15 minutes.

INFORMATION

▪ If the dust does NOT come off easily, wash them with a

neutral detergent diluted in lukewarm water. Dry the air
filters in the shade.

▪ It  is  recommended  to  clean  the  air  filters  every  2

weeks.

Summary of Contents for Siesta ATX-R

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner ATXM20R2V1B ATXM20R5V1B ATXM25R2V1B ATXM25R5V1B ATXM35R2V1B ATXM35R5V1B ATXM50R2V1B...

Page 2: ...less LAN connection 12 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving and...

Page 3: ...rted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are P...

Page 4: ...erant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourl...

Page 5: ...door unit display ON OFF a b c d e a Signal receiver for user interface b Operation lamp c Timer lamp d Intelligent eye lamp e ON OFF button ON OFF button If the user interface is missing you can use...

Page 6: ...Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Use the system in the following temperature and humidi...

Page 7: ...32 C 10 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 5 3 Airflow rate 1...

Page 8: ...so may lead to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The las...

Page 9: ...MATION The high speed electrons are generated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharg...

Page 10: ...30 25 C 27 C 25 C 22 00 1 2 3 4 ON OFF ON OFF Saturday No timer setting Sunday Make up to 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling...

Page 11: ...Press to complete the setting Result is displayed on the LCD Note To change the reservation setting after copying refer to 5 10 1 To set Weekly timer operation 410 5 10 3 To confirm reservations You...

Page 12: ...l communicate with your smart device in your home network using a modem router or a similar device For more information and FAQ refer to http www onlinecontroller daikineurope com 1 Stop operation bef...

Page 13: ...ing 2 Change to the SP menu by pressing twice or repeatedly 2 5 sec 3 Hold for at least 2 seconds to confirm the selection Result is blinking The operation and timer LEDs are blinking at the same time...

Page 14: ...GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the unit is mildly flammable but normally does NOT le...

Page 15: ...a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 4 To remove the front panel 1 Hold the front panel by the panel tabs on both sides and open it 2 Remove the front p...